IEEE 1309-2013 PDF

IEEE 1309-2013 PDF

IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz

$103.50 $207.00 -50%
isbn 9780738187440
Product Code: IEEE 1309
Stock In Stock
Published: 11/22/2013
Number of Pages: 111
File Size: 1 file, 2.3 MB

Available Options

Product Description

IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz

Introduction: This introduction is not part of IEEE Std 1309-2013, IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz. This standard provides calibration methods for electromagnetic (EM) field sensors and probes, excluding antennas per se, for the frequency range of 9 kHz to 40 GHz. The original version of this standard was developed and released in 1996 in response to need within the electromagnetic compatibility (EMC) test and measurement community for standard (consensus) methods of calibration for commonly used EM field sensors and probes. The 2005 version of the standard provided updates to the original 1996 version to clarify items that some users may have found difficult to understand, to expand details and examples with respect to estimating and expressing calibration uncertainty, and to present additional technical background information. Also, the 2005 version inserted calibration methods for field probes used for specific types of commercial electronic products radiated immunity testing i.e., IEC 61000-4-3:2006 [B48]a, and H-field probe calibrations applicable for ANSI C63.19-2007 [B3] hearing aid and wireless communication device compatibility testing. The 2013 version of the standard consolidates field generation setups and calculation methods with test methods specified in probe calibrations for typical commercial electronics products radiated immunity setups, and improves consistency in primary field calculatio

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 1.3 Other considerations and background
  • 1.4 Generic probe types
  • 4.1 Calibration methods
  • 4.2 Field sensor or probe orientation during calibration
  • 6.1 General considerations
  • 6.2 Standard uncertainty
  • 6.3 Combined standard uncertainty
  • 6.4 Expanded uncertainty
  • 6.5 Reporting uncertainty
  • 7.1 Dynamic range and amplitude calibration levels
  • 7.2 Frequency response
  • 7.3 Isotropy
  • 7.4 Response time (optional)
  • 7.5 Time constant (optional)
  • 7.6 Modulation response (optional)
  • 8.1 General
  • 8.2 Transfer standard method
  • 8.3 Frequency domain calibration procedure
  • 9.1 Proper documentation
  • 9.2 Test documentation
  • 9.3 Calibration interval
  • 9.4 Out-of-tolerance notification
  • 9.5 Certification to client or end-user