IEEE 1547.7-2013 PDF

IEEE 1547.7-2013 PDF

IEEE Guide for Conducting Distribution Impact Studies for Distributed Resource Interconnection

$109.50 $219.00 -50%
isbn 9780738188720
Product Code: IEEE 1547.7
Stock In Stock
Published: 02/28/2014
Number of Pages: 129
File Size: 1 file, 1.3 MB

Available Options

Product Description

IEEE Guide for Conducting Distribution Impact Studies for Distributed Resource Interconnection

Introduction: This introduction is not part of IEEE Std 1547.7™-2013, IEEE Guide for Conducting Distribution Impact Studies for Distributed Resource Interconnection. With the advent of IEEE Std 1547™-2003, modern interconnection equipment has made great gains by having universal interconnection and test requirements focused at the point of common coupling. Additionally, since the adoption of IEEE Std 1547™, there has been significant experience gained related to inter-related technology systems and operational concepts to properly integrate distributed resources (DR) into electric power systems (EPS). Traditionally, however, utility electric power systems were not designed to accommodate active generation and storage at the distribution level. The addition of DR to an EPS will change the system and its response in some manner. Increased adoption of distributed resources throughout distribution systems often results in the need to perform a distribution system impact study. This guide provides a common technical platform based on engineering knowledge to address study methods for performing DR-EPS impact studies. This document includes an overview of general considerations, operational considerations, configuration considerations, preliminary review criteria, conventional and special impact studies methodologies, tools and technical issues, data requirements, and examples of mitigation techniques. A sample methodology for using the guide is also provided. The intended audience will gain a c

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 1.3 Intended audience
  • 1.4 Limitations
  • 1.5 Document structure
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 Potential DR impacts on the Area EPS
  • 4.2 DR primary energy source-related considerations
  • 4.3 DR technology-specific considerations
  • 4.4 Area EPS-related considerations
  • 5.1 DR attributes affecting interconnection
  • 5.2 Area EPS attributes affecting interconnection
  • 7.1 Introduction
  • 7.2 Criteria ID P1—Use of certified DR equipment
  • 7.3 Criteria ID P2—Potential for unintended islands
  • 7.4 Criteria ID P3—Impact on EPS equipment loading under all steady state conditions
  • 7.5 Criteria ID P4—Impacts on system protection, fault conditions, and arc flash rating
  • 7.6 Criteria ID P5—Impacts on voltage regulation within the EPS under steady state conditions
  • 7.7 Criteria ID P6—Impacts on EPS power quality
  • 8.1 Introduction
  • 8.2 Study ID C1—Steady state simulation
  • 8.3 Study ID C2—System protection studies
  • 8.4 Study ID C3—Operational characteristics—loading, load shedding, etc.
  • 9.1 Introduction
  • 9.2 Technical basis for the studies
  • 9.3 Study methodologies
  • 9.4 Study ID S1—Quasi-static simulation
  • 9.5 Study ID S2—Dynamic simulation
  • 9.6 Study ID S3—Electromagnetic transient simulation

Be the first to write a review for this product.