IEEE 1653.6-2018 PDF

IEEE 1653.6-2018 PDF

IEEE Recommended Practice for Grounding of DC Equipment Enclosures in Traction Power Distribution Facilities

$30.50 $61.00 -50%
isbn 9781504453080
Product Code: IEEE 1653.6
Stock In Stock
Published: 12/10/2018
Number of Pages: 21
File Size: 1 file, 970 KB

Available Options

Product Description

IEEE Recommended Practice for Grounding of DC Equipment Enclosures in Traction Power Distribution Facilities

Introduction: This introduction is not part of IEEE Std 1653.6™-2018, IEEE Recommended Practice for Grounding of DC Equipment Enclosures in Traction Power Distribution Facilities. This document contains recommended practices for grounding and bonding of dc equipment enclosures installed within traction power distribution facilities where the conventional practice in most dc traction power systems is to isolate both the positive and negative poles from ground. There exists a variety of system grounding methods, including single-point grounding, positive- or negative-pole grounding, resistive grounding, diode grounding, etc; however, details on system grounding and related applications, e.g., stray current control, rail-to-ground protective relay devices, are not covered by the scope of this document. For additional information regarding transit power systems grounding, refer to IEEE Std 142™, IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems.a, b, c The necessity of this recommended practice stems from the lack of uniformity of enclosure grounding practices in the dc traction industry. Furthermore, grounding of dc traction equipment enclosures is not covered in the National Electric Code® (NEC®) [B4]d or the National Electrical Safety Code® (NESC®) [B1]. As such, the goal of this document is to provide users with the various grounding methods used specifically for grounding dc traction equipment enclosures and preparing dc traction distribution facilities wh

Contents:

  • 1.1 Background
  • 1.2 Scope
  • 1.3 Purpose
  • 5.1 Background on dc equipment enclosures
  • 5.2 NEC requirements
  • 5.3 Solid grounding
  • 5.4 High-resistance enclosure grounding
  • 5.5 Low-resistance enclosure grounding
  • 6.1 Background on floor insulation practices
  • 6.2 Dielectric withstand test
  • 6.3 Metal plate method
  • 7.1 Background on wall insulation practices
  • 7.2 Dielectric withstand test
  • 7.3 Test methods

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 1653.6-2018 PDF

IEEE 1653.6-2018 PDF

$30.50 $61.00