IEEE Standard for Power Line Communication Equipment--Electromagnetic Compatibility (EMC) Requirements--Testing and Measurement Methods

Introduction: This introduction is not part of IEEE Std 1775-2010, IEEE Standard for Power Line Communication Equipment— Electromagnetic Compatibility (EMC) Requirements—Testing and Measurement Methods. Power line communication (PLC) technology has developed over a long period of time. As early as 1838 Edward Davy proposed remote electricity supply metering for the purpose of checking the voltage levels of the batteries at unmanned sites in the London-Liverpool telegraph system. The first carrier-current system for mains signaling was established in 1893 by the Swiss Electricity Board. The carrier frequency transmission of voice over power lines began in the 1920s. Due to low attenuation and low noise in the transmission lines at the carrier frequencies (15 KHz to 500 KHz), a distance of 900 km between transmitter and receiver could be attained with a power of 10 W. In 1930 Ripple Carrier Signaling was implemented in Germany over medium- and low-voltage distribution power lines. Such systems typically operated in the frequency band 125 Hz to 3000 Hz, so a carrier signal propagated with low losses. Advances in communication technology in the late 1990’s led to new research and development activities related to data communication through the power grid. Known widely as power line communications (PLC), this technology is also named broadband over power line (BPL), power line telecommunication (PLT), and power line technology (PLT). PLC created a mix of high expectations and concerns mainly du

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 Definitions
  • 3.2 Acronyms
  • 4.1 Topologies
  • 4.2 Physical differences
  • 4.3 Electrical non-BPL equipment
  • 4.4 Power line noise
  • 4.5 Examples of typical installation
  • 4.6 Description of ports
  • 5.1 In-premises BPL equipment
  • 5.2 Access BPL equipment
  • 6.1 Radiated emission testing
  • 6.2 Immunity testing
  • 7.1 Access equipment
  • 7.2 In-premises equipment
  • 7.3 Radiated emission measurement uncertainty
  • 7.4 Test report template
  • 8.1 Electrostatic discharge
  • 8.2 Electrical fast transient/burst
  • 8.3 Surges
  • 8.4 Continuous conducted signals
  • 8.5 Radiated electromagnetic field
  • 8.6 Voltage dips and interruption
  • 8.7 Power frequency magnetic field
  • 8.8 Performance criteria and applicability
  • 8.9 Test report template