IEEE 367-2012 PDF

IEEE 367-2012 PDF

IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault

$137.50 $275.00 -50%
isbn 9780738172651
Product Code: IEEE 367
Stock In Stock
Published: 05/21/2012
Number of Pages: 168
File Size: 1 file, 16 MB

Available Options

Product Description

IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault

Introduction: This introduction is not part of IEEE Std 367-2012, IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault. Wire-line telecommunication facilities serving electric power stations often require that extraordinary protection measures be taken to protect against the effects of fault-produced ground potential rise (GPR) or induced voltages, or both. In the presence of a hostile electromagnetic environment, suitably rated protection equipment is required at the power station for personnel safety, for the protection of the serving telecommunication facilities, and to help ensure the desired continuity of telecommunication transmission at times of power system faults. There is a fundamental need, therefore, to determine the appropriate values of fault-produced GPR and induction, including considerations of their probability and duration, to be used in developing the specifications and ratings for the protection equipment to be used in any given application. This recommended practice provides information for the determination of the appropriate values of fault- produced power station GPR and induction for use in the design of protection systems. Included are the following: a) The determination of the appropriate value of fault current to be used in the GPR calculation b) The consideration of the waveform, probability, and duration of the fault current c) The determination of inducing currents, the mutual imped

Contents:

  • 1.1 Scope
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 Telecommunication facilities
  • 4.2 Faults on power systems
  • 4.3 Power station ground grid impedance to remote earth
  • 4.4 Establishing net fault current values
  • 4.5 Division of fault current
  • 4.6 Calculating the inducing current
  • 4.7 Ground potential rise
  • 4.8 Sources of fault and inducing current information and impedance to remote earth information
  • 4.9 Transient voltages resulting from power system operation
  • 4.10 Types of wire-line telecommunication circuits usually requested for electric power stations
  • 4.11 Service types and performance objectives for telecommunication services provided at
  • 5.1 Determination of appropriate symmetrical and asymmetrical GPR
  • 5.2 Duration of the fault and its relationship to wire-line telecommunication requirements for
  • 5.3 Extraordinary possibilities
  • 5.4 Example of a GPR calculation and volt-time area calculation
  • 5.5 Summary
  • 5.6 Multigrounded neutral impedance in rural areas
  • 5.7 GPR calculations for distributed generation
  • 6.1 Inducing current
  • 6.2 Mutual impedance
  • 6.3 General equation
  • 6.4 Examples of calculations
  • 6.5 Cumulative mutual impedance and electromagnetic induction curves
  • 6.6 Correction for difference in line heights
  • 6.7 Electric supply line with double-end feed
  • 6.8 Fault location for maximum induced voltage
  • 6.9 Shield factor