IEEE 43-2013 PDF

IEEE 43-2013 PDF

IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery

$43.50 $87.00 -50%
isbn 9780738189376
Product Code: IEEE 43
Stock In Stock
Published: 03/06/2014
Number of Pages: 37
File Size: 1 file, 2 MB

Available Options

Product Description

IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery

Introduction: This introduction is not part of IEEE Std 43™-2013, IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery. Insulation resistance measurement has been recommended and used for more than half a century to evaluate the condition of electrical insulation. Whereas individual insulation resistance measurements may be of questionable value, the carefully maintained record of periodic measurements, accumulated over months and years of service, is of unquestioned value as a measure of some aspects of the condition of the electrical insulation. Originally, in 1950, this recommended practice was published by the AIEE as a guide to present the various facets associated with the measurement and understanding of electrical insulation resistance. The guide was revised in 1961 and again in 1974. During the 1970s, several changes were made to the types of insulation used in electric rotating machines. The insulation resistance characteristics of these newer THERMOSETTING insulation systems are different from the older THERMOPLASTIC systems, and therefore required this substantial revision to the standard for measuring insulation resistance. Other changes include the addition of further description of the testing theory and the removal of suggestions regarding maintenance dry-out procedures for older windings (previously Annex A). Recommendations for maintenance procedures are beyond the scope of this document. With this publication as a recommended practice, the IE

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 5.1 Components of the measured direct current
  • 5.2 Characteristics of the measured direct current
  • 5.3 Insulation resistance readings
  • 5.4 Polarization index readings
  • 5.5 Discharge current
  • 6.1 Effect of surface condition
  • 6.2 Effect of moisture
  • 6.3 Effect of temperature
  • 6.4 Effect of test voltage magnitude
  • 6.5 Effect of existing charge on winding resistance measurements
  • 9.1 Direct measurement
  • 9.2 Calculated measurement
  • 11.1 Monitoring insulation condition
  • 11.2 Suitability for operation or continued testing
  • 11.3 Limitations of the insulation resistance test
  • 12.1 Minimum values
  • 12.2 Polarization Index
  • 12.3 Insulation resistance

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 43-2013 PDF

IEEE 43-2013 PDF

$43.50 $87.00