IEEE 487.1-2014 PDF

IEEE 487.1-2014 PDF

IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment

$43.50 $87.00 -50%
isbn 9780738193779
Product Code: IEEE 487.1
Stock In Stock
Published: 11/07/2014
Number of Pages: 39
File Size: 1 file, 3.4 MB

Available Options

Product Description

IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment

Introduction: This introduction is not part of IEEE Std 487.1™-2014, IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment. Wire-line telecommunication facilities serving electric supply locations often require special high-voltage protection against the effects of fault-produced ground potential rise (GPR) or induced voltages, or both. Some of the telecommunication services are used for control and protective relaying purposes and may be called upon to perform critical operations at times of power-system faults. This requirement presents a major challenge in the design and protection of the telecommunication system because power-system faults can result in the introduction of interfering voltages and currents into the telecommunication circuit at the very time when the circuit is most urgently required to perform its function. Even when critical services are not involved, special high-voltage protection may be required for both personnel safety and plant protection at times of power-system faults. Effective protection of any wire-line telecommunication circuit requires coordinated protection on all circuits provided over the same telecommunication cable. Some electrical environments, collectively called electric supply locations, require the application of unique electrical protection techniques because of their special nature. One such environment is the electric power station or substation

Contents:

  • 1.1 Background
  • 1.2 Scope
  • 1.3 Purpose
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 Locations
  • 4.2 Practical implications
  • 4.3 Earth potential profile
  • 4.4 Cables in high-voltage environments
  • 5.1 Background
  • 5.2 Concepts and concerns
  • 5.3 Service performance objective (SPO) classifications
  • 5.4 Responsibilities for installation and maintenance
  • 5.5 General-use telecommunication cable in the electric supply location GPR ZOI
  • 5.6 Dedicated cable
  • 5.7 Special wire-line protection design requirements
  • 6.1 Ground potential rise (GPR) plus induced voltage levels
  • 6.2 Basic protection system
  • 6.3 Protection configurations employing isolation devices
  • 6.4 General isolation protection configuration
  • 6.5 Protection configuration employing modular high dielectric and optic isolators
  • 6.6 Protection practices for electric supply locations services
  • 8.1 General safety considerations
  • 8.2 Safety considerations in equipment design
  • 8.3 Safety considerations related to installation and maintenance

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 487.1-2014 PDF

IEEE 487.1-2014 PDF

$43.50 $87.00