IEEE C37.114-2014 PDF

IEEE C37.114-2014 PDF

IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines

$73.50 $147.00 -50%
isbn 9781504401296
Product Code: IEEE C37.114
Stock In Stock
Published: 01/30/2015
Number of Pages: 72
File Size: 1 file, 3.5 MB

Available Options

Product Description

IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines

Introduction: This introduction is not part of IEEE Std C37.114-2014, IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines. This guide outlines the techniques and application considerations for determining the location of a fault on ac transmission and distribution lines. The guide reviews traditional approaches and the primary measurement techniques used in modern devices: one- and two-terminal impedance-based methods and traveling-wave methods. Application considerations include: two- and three-terminal lines, series- compensated lines, parallel lines, untransposed lines, underground cables, fault resistance effects, and other power system conditions, including those unique to distribution systems. Copyright © 2015 IEEE. All rights reserved.

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 1.3 Techniques and requirements for fault-locating devices
  • 1.4 How to determine line parameters
  • 2.1 Definitions
  • 2.2 Acronyms and abbreviations
  • 3.1 Background
  • 3.2 Implementation: data and equipment required
  • 3.3 Determination of measurement error
  • 3.4 Error due to reactance effect
  • 3.5 Algorithms
  • 4.1 Background
  • 4.2 Implementation requirements
  • 4.3 System parameters
  • 4.4 Algorithms
  • 5.1 Three-terminal lines
  • 5.2 Series-compensated lines
  • 5.3 Parallel lines
  • 5.4 Tapped lines
  • 5.5 Distribution system faults
  • 5.6 Locating faults on underground cables and paralleled cable circuits
  • 5.7 Automatic reclosing effects on fault locating
  • 5.8 Effect of tapped load
  • 5.9 Phase selection, fault identification, sequential faults
  • 5.10 Long lines and reactor and capacitor installations
  • 5.11 Short duration faults
  • 5.12 Effect of untransposed lines on accuracy of line parameters
  • 5.13 Comparison of one- and two-terminal impedance-based methods
  • 5.14 Fault location for nonhomogeneous transmission lines
  • 6.1 Background

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE C37.114-2014 PDF

IEEE C37.114-2014 PDF

$73.50 $147.00