IEEE C37.302-2015 PDF

IEEE C37.302-2015 PDF

IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC

$44.00 $88.00 -50%
isbn 9781504408318
Product Code: IEEE C37.302
Stock In Stock
Published: 05/18/2016
Number of Pages: 53
File Size: 1 file, 3.3 MB

Available Options

Product Description

IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC

Introduction: This introduction is not part of IEEE Std C37.302-2015, IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC. Significant developments in the area of fault current limiters (FCLs) operating on the principle of condition-based impedance increase have resulted in products emerging on the market in the last decade. There are, however, no guidelines on how to test these new FCL technologies. Therefore, in June 2010 the IEEE Switchgear Committee established WG PC37.302 to develop such a guide. This Working Group was co-sponsored by the IEEE Power and Energy Society/Substations (PE/SUB) and the IEEE Power Electronics Society/Standards Committee (PEL/SC). This guide takes a technology- independent black-box approach and intentionally avoids stating any performance criteria. It provides, however, a newly developed set of parameters (not values) to fully describe the behavior of any FCL for testing purposes. Overall, this guide has been written to inform the stakeholder community about all the aspects of testing FCLs. Copyright © 2016 IEEE. All rights reserved.

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 General FCL definitions
  • 3.2 Definitions related to voltages observed during fault current limitation
  • 3.3 Definitions related to prospective short-circuit currents
  • 3.4 Definitions related to initiation of CCL transition
  • 3.5 Definitions related to currents without limitation by an FCL
  • 3.6 Fault currents or over-currents with limitation by an FCL
  • 3.7 FCL recovery processes and associated times
  • 4.1 Type A FCLs
  • 4.2 Type B FCLs
  • 5.1 Electrical performance
  • 5.2 Rated fault current limitation voltage
  • 5.3 Rated maximum prospective short-circuit current
  • 5.4 Rated minimum prospective short-circuit current
  • 5.5 Withstand current ratings in C mode
  • 5.6 CCL Initiation criteria
  • 5.7 Current ratings with FCL limitation
  • 5.8 Insertion impedance
  • 5.9 Physical and operational
  • 5.10 Environmental
  • 5.11 Safety
  • 6.1 Aspects of FCL behavior
  • 6.2 Power frequency voltage withstand test
  • 6.3 Lightning impulse voltage
  • 6.4 Switching impulse voltage
  • 6.5 Chopped-wave lightning impulse voltage
  • 6.6 Surge current test (alternate)
  • 6.7 Partial discharge
  • 6.8 Control circuit design test

Be the first to write a review for this product.

Write a review