IEEE Guide for Paralleling Regulating Transformers

Introduction: This introduction is not part of IEEE Std C57.153-2015, IEEE Guide for Paralleling Regulating Transformers. This guide was prepared by the C57.153 Working Group of the Power Transformers Subcommittee of the Transformers Committee of the IEEE Power and Energy Society. The intent of this new guide is to present information for the selection and application of transformer paralleling methods used to maintain power system operations. This guide describes paralleling methods in common practice at the time this guide was written and provides information concerning the operational requirements and limitations of each method. Additional information is provided for cases of paralleling transformers with unequal ratings and other operational conditions requiring special considerations. Copyright © 2015 IEEE. All rights reserved.

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 General application
  • 4.2 Reasons for paralleled transformer operation
  • 4.3 Basic voltage-control operation
  • 4.4 Effects of off-tap operation
  • 4.5 Consequences of less-than-optimal paralleling operation
  • 4.6 Regulating transformer/system requirements for parallel operation
  • 5.1 Need for paralleling operation control
  • 5.2 Basic paralleling control requirements
  • 6.1 Regulating transformers
  • 6.2 Step-voltage regulators
  • 7.1 Paralleled transformer impedance
  • 7.2 Unequal voltage-regulating tap-sizes and ranges
  • 7.3 Transformers with multiple windings
  • 7.4 Multiple (greater than two) paralleled transformers
  • 7.5 Source bus configurations
  • 8.1 Operating principle
  • 8.2 Control arrangements
  • 8.3 Settings and sensitivity
  • 8.4 Backup methods
  • 8.5 Effects of non-similar transformers/configuration
  • 8.6 Frequent application errors
  • 9.1 Operating principle
  • 9.2 Control arrangements
  • 9.3 Settings and sensitivity
  • 9.4 Backup methods
  • 9.5 Effects of non-similar transformer/configuration