IEEE Guide for Loading Dry-Type Distribution and Power Transformers

$60.50 $121.00 -50%
isbn 9781504415859
Product Code: IEEE C57.96
Stock In Stock
Published: 01/27/2014
Number of Pages: 46
File Size: 1 file, 770 KB

Available Options

Product Description

IEEE Guide for Loading Dry-Type Distribution and Power Transformers

Introduction: This introduction is not part of IEEE Std C57.96-2013, IEEE Guide for Loading Dry-Type Distribution and Power Transformers. This guide covers the loading of dry-type distribution and power transformers and has been developed to cover modern dry-type transformers through 10 000 kVA. The insulation systems referred to in this document meet the thermal evaluation criteria established by the now withdrawn IEEE Std C57.12.56™- 1986a or the replacement document, IEEE Std C57.12.60™. Work completed by the IEEE Insulation Life Subcommittee, comprising life test on transformer models, is the basis for the insulation life versus temperature relationship, designated as minimum life expectancy in IEEE Std C57.12.56-1986 and IEEE C57.12.60, which in turn are based on the Arrhenius reaction rate theory. To avoid ambiguity, this guide will use the term “life expectancy” to indicate the life to be expected at a given temperature. The “normal life expectancy” at rated hottest-spot temperature in a 30 °C ambient is expected to be 20 years. For calculation purposes, 180 000 h is used as the expected lifetime. This revision of the guide combined the content for all dry-type transformers, including those with solid- cast and/or resin-encapsulated epoxy windings into the main body of the document. In addition, the computer programs in Annex B have been updated to include all transformer types, and detailed examples of loading and aging have been provided in Annex C. Moreover, the document has been

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 4.1 General information
  • 4.2 Transformer life expectancy
  • 4.3 Transformer rated output
  • 4.4 Aging of insulation
  • 4.5 Ambient temperature
  • 5.1 Continuous loading
  • 5.2 Transient loading
  • 5.3 Time constants
  • 5.4 Calculation of loading capability
  • 6.1 Basic conditions
  • 6.2 Factors affecting transformer life
  • 6.3 Lifetime
  • 6.4 Example deriving lifetime calculation constants
  • 6.5 Method of converting actual load cycle to equivalent constant load
  • 6.6 Temperature limits for loading above rating
  • 6.7 Daily load calculations
  • 6.8 Other limitations