IEEE C62.72-2016 PDF

IEEE C62.72-2016 PDF

IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits

$85.50 $171.00 -50%
isbn 9781504419918
Product Code: IEEE C62.72
Stock In Stock
Published: 06/10/2016
Number of Pages: 107
File Size: 1 file, 3.7 MB

Available Options

Product Description

IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits

Introduction: This introduction is not part of IEEE Std C62.72-2016, IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of the Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits. One purpose of this guide is to provide specifiers, users, and manufacturers of surge-protective devices (SPDs) with an understanding of numerous application considerations to be evaluated before SPDs are installed in low-voltage ac power circuits. Given this understanding, specifiers, users and manufacturers can exercise due diligence in applying SPDs, take steps to prevent their misapplications, and act to either prevent or mitigate adverse effects that SPDs may have on a power distribution system (PDS) in an effort to improve the effectiveness and benefit of applying SPDs to the PDS. The growth of interest in and use of low-voltage power SPDs parallels the increasing number of installations with sensitive, sophisticated, and expensive electronic equipment and components that can be exposed and susceptible to surge voltages. It must be recognized that SPDs are not designed to correct every type of power system disturbance. However, SPDs can be extremely effective at mitigating the impact of transient overvoltages or surges. The functionality of any SPD is directly related to the specific location where it is connected to a low-voltage PDS and the methods used to make the required electrical connections to the PDS. SPDs installed at various locatio

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 5.1 Lightning
  • 5.2 Switching
  • 6.1 No observed change
  • 6.2 Upset
  • 6.3 Damage
  • 6.4 Consequential damage
  • 7.1 General
  • 7.2 Environmental factors
  • 7.3 Changes in the power distribution system (PDS)
  • 7.4 Rate of occurrence (versus) current level
  • 7.5 Exposure levels
  • 7.6 Risk assessments
  • 9.1 System configuration
  • 9.2 System arrangement or distribution
  • 9.3 Examples of system voltages
  • 9.4 Available short-circuit current and SPD short-circuit current rating
  • 9.5 Voltage ratings of SPDs
  • 10.1 Grounded (earthed) systems
  • 10.2 Impedance (resistance) grounded systems
  • 10.3 Ungrounded (unearthed) systems
  • 10.4 Ferroresonance
  • 11.1 SPD grounding lead and related considerations
  • 11.2 Common bonding network
  • 11.3 Grounding
  • 11.4 Ground (earth) potential rise (GPR/EPR)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE C62.72-2016 PDF

IEEE C62.72-2016 PDF

$85.50 $171.00