IEEE Standard for Interrupter Switches for Alternating Current, Rated Above 1000 Volts
Introduction: Over many years, standards covering interrupter switches have been developed in subcommittees other than the High Voltage Switch Subcommittee. As a result, different and sometimes conflicting requirements for interrupter switches have been developed. Where there is a clear need for different requirements in different applications, diverging standards are appropriate. However, where application requirements are similar, the body of standards should treat the requirements uniformly. As a result of this philosophy, the Switchgear Administrative Subcommittee passed the following motion at the May 1991 meeting in Fort Lauderdale. In an effort to promote a uniform approach to standards, the following policy is set: Future standards and revisions to standards that incorporate fuses, switches, circuit breakers, and/or reclosers and sectionalizers shall reference the basic fuse, switch, circuit breaker, and/or recloser and sectionalizer standard wherever possible and treat material differently only when there are unique application requirements. This standard was written to provide the basic standard for interrupter switches. As such, an attempt was made to encompass as many different types of interrupter switches as practical. This standard has also provided the opportunity to update and revise the general treatment of interrupter switches, and address newer technologies that are being used to provide switching functions. Part of the heritage of this document comes from the treatment
Scope: This standard applies to switching devices, interrupters, and interrupter switches (as defined in IEEE Std C37.100™) for alternating current, rated above 1000 V and used indoors, outdoors, or in enclosures for which a switching rating is to be assigned. While this standard covers the basic requirements of interrupter switches used indoors, outdoors, and in enclosures, other standards such as IEEE Std C37.20.2™, IEEE Std C37.20.3™, IEEE Std C37.20.4™, and IEEE Std C37.74™ also contain requirements for switches used in enclosures. This standard does not apply to load-break separable insulated connectors, which are covered by IEEE Std 386™-1995 [B8].1 This standard also does not apply to circuit-breakers, circuit-switchers, or reclosers. Purpose The purpose of this standard is to provide a basic standard for switches as defined in 3.5. The broad definition of a switch, given in 3.5, encompasses devices that meet the strict definition of an interrupter switch in IEEE Std C37.100, and also encompass devices that utilize insulating media other than air.
Contents:
- 1.1 Scope
- 1.2 Purpose
- 4.1 Usual service conditions
- 4.2 Unusual service conditions
- 5.1 Rated power frequency
- 5.2 Rated voltage
- 5.3 Rated withstand voltages
- 5.4 Rated currents
- 5.5 Rated ice breaking ability
- 5.6 Rated control voltage
- 5.7 Rated mechanical operations
- 5.8 Rated mechanical terminal load
- 5.9 Visible corona-free voltage
- 5.10 Radio-influence voltage limit
- 5.11 Partial discharge limits
- 6.1 Preferred ratings—Outdoor switches
- 6.2 Preferred ratings—Indoor switches
- 6.3 Preferred ratings—Enclosed switches
- 6.4 Other preferred ratings
- 7.1 Nameplates
- 7.2 Contact position indicator
- 7.3 Accessories
- 7.4 Instructions
- 7.5 Terminal pads
- 8.1 Withstand voltage tests
- 8.2 Continuous current tests
- 8.3 Switching tests