IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Transmission and Distribution Facilities

Introduction: This introduction is not part of IEEE Std 1613.1-2013, IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Transmission and Distribution Facilities. This document is an extension of IEEE Std 1613™-2009 and its amendment (IEEE Std 1613a™-2011) from two perspectives. The scope has been broadened to include devices installed in all electric power facilities, not just substations, and includes the communications modules installed in Smart Meters. It adds two installation zones—(Zone A) inside a facility’s building/control house or fenced area, and (Zone B) outside these buildings or fenced areas. Thus, it is expressly applicable for devices used for distribution automation and distributed generation. Added are the device testing and performance requirements for communications via radio frequency (RF), via power line carrier/communications, via Broadband over Power Line (BPL), or via Ethernet cable. Five IEC immunity tests have also been added as suggested in the SGIP-EMI Issues White paper [B5]a with specific immunity levels for Zone A and Zone B installations. The test conditions and acceptance criteria in Annex A have been revised to help ensure that the transmit function of the device is exposed to the test conditions at some point during the tests in Clause 5 through Clause 12. This is a new requirement in this text, and may not be a requirement in other standards. The requirements in Clause 6 of IEEE Std 1613-2009 regarding

Contents:

  • 1.1 Scope
  • 1.2 Need for the project
  • 4.1 Service installation
  • 4.2 Operational temperature range
  • 5.1 Scope
  • 5.2 Test profile for RF and power line carrier/communication devices
  • 5.3 Installation Zone B—Oscillatory and fast transient SWC test levels
  • 6.1 Surge test generator
  • 6.2 Surge test levels
  • 7.1 Test definition and scope
  • 7.2 Tests from 80 MHz to 1.0 GHz—severity levels
  • 7.3 Additional frequencies for frequency sweep and spot frequency tests for devices installed in both
  • 7.4 RF hazards
  • 8.1 ESD test description
  • 8.2 Test acceptance criteria
  • 9.1 Test procedures and levels
  • 10.1 Power frequency immunity
  • 10.2 Power frequency test levels
  • 11.1 Immunity requirements
  • 11.2 Test levels
  • 12.1 Immunity requirements
  • 12.2 Test levels