Introduction: This introduction is not part of IEEE Std 1783-2009 IEEE Guide for Test Methods and Procedures to Evaluate the Electrical Performance of Insulators in Freezing Conditions. In many cold climate regions, overhead transmission and distribution lines as well as their substation equipment are subjected to ice and snow accumulations that may be contaminated in the same ways that affect natural rain. Insulator standards presently call for a wet test at a controlled rain rate but do not recommend icing test methods. While the electrical withstand in a wet test is well above typical service voltage stress, this may not be the case in cold conditions. Certain sequences of ice or snow accumulation and melting may cause a drastic decrease in electrical insulation strength. Especially of highly stressed, extra high-voltage and ultra high-voltage insulators, this can lead to insulator flashovers at normal service voltage and power outages. Flashover problems on ice- and snow-covered insulators have been reported in North America and many countries including China, Czech Republic, England, Finland, Japan, Norway, Switzerland, Sweden, and the former Yugoslavia. The industry need for insulation coordination in the affected countries was a source of motivation to establish an IEEE Task Force on Insulator Icing Test Methods in 1999. In 2003, this Task Force recommended icing test methods and procedures in “Insulator icing test methods and procedures—A position paper prepared by the IEEE Task Fo

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 Testing criteria
  • 4.2 Testing methods
  • 4.3 Electrical clearances and configuration
  • 4.4 Discharge observation and interpretation
  • 4.5 Power supply requirements
  • 4.6 Test object preparation before testing
  • 5.1 Ice test for air break disconnect switches
  • 5.2 Preparation of object for ice tests
  • 5.3 Methods and parameters for ice exposure
  • 5.4 Evaluation of flashover voltage for ice tests
  • 5.5 Evaluation of ice test criteria
  • 6.1 General
  • 6.2 Preparation of object for snow test
  • 6.3 Methods and parameters for snow exposure
  • 6.4 Evaluation of flashover voltage for snow tests
  • 7.1 General
  • 7.2 Preparation of object for cold-fog test
  • 7.3 Methods and parameters for cold-fog exposure
  • 7.4 Evaluation of flashover voltage in cold-fog test
  • 7.5 Evaluation of cold-fog test criteria
  • 8.1 Preparation of object for salt-fog test
  • 8.2 Methods and parameters for salt-fog exposure at freezing temperatures
  • 8.3 Evaluation of flashover voltage in salt-fog test
  • 8.4 Evaluation of salt-fog test criteria