IEEE 1894-2015 PDF

IEEE 1894-2015 PDF

IEEE Guide for Online Monitoring and Recording Systems for Transient Overvoltages in Electric Power Systems

$44.00 $88.00 -50%
isbn 9780738199115
Product Code: IEEE 1894
Stock In Stock
Published: 12/18/2015
Number of Pages: 61
File Size: 1 file, 3.8 MB

Available Options

Product Description

IEEE Guide for Online Monitoring and Recording Systems for Transient Overvoltages in Electric Power Systems

Introduction: This introduction is not part of IEEE Std 1894™-2015, IEEE Guide for Online Monitoring and Recording Systems for Transient Overvoltages in Electric Power Systems. Transmission and transformation apparatuses in power systems may be subject to lightning overvoltage or switching overvoltage at any time. Lightning overvoltage may invade transmission lines and cause failure when a substation has many output transmission lines or lightning is located in the incidence area. Internal overvoltage may occur when a no-load transmission line or a no-load transformer is removed from the system. A grounding fault may cause arc grounding overvoltage. The value of these overvoltages can reach two to five times the system’s operating voltage. If insulation coordination is improper or defective in substations, overvoltages may cause damage to primary equipment. Furthermore, if the insulation of an apparatus is defected or aged, overvoltages may cause insulation breakdown. Existing standards on measuring and recording overvoltages are not mainly applied to transient overvoltages but are applied to power frequency overvoltage in power systems. Transient overvoltages are different to power frequency overvoltage in waveform, amplitude, measuring equipment, and measuring technique. This standard is developed to standardize the techniques for online monitoring and recording of the transient overvoltages.

Contents:

  • 3.1 Definitions
  • 3.2 Subscripts, symbols, and acronyms
  • 4.1 Configuration of online monitoring and recording systems for transient overvoltages
  • 4.2 Functions of an online monitoring and recording system for transient overvoltages
  • 5.1 Overvoltage ranges
  • 5.2 Dividing modes
  • 5.3 Bandwidths of different dividing modes
  • 5.4 The selection of divider systems
  • 5.5 Specification requirements
  • 6.1 Definition
  • 6.2 Configurations of a recording system
  • 6.3 Specification requirements
  • 7.1 Basic requirements
  • 7.2 Selection of major components
  • 7.3 Technical requirements for online measuring equipment connection
  • 8.1 Evaluation and expression of uncertainty in data measurement
  • 8.2 Requirements for total uncertainty of measuring systems

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 1894-2015 PDF

IEEE 1894-2015 PDF

$44.00 $88.00