IEEE 2745.3-2020 PDF

IEEE 2745.3-2020 PDF

IEEE Guide for Technology of Unified Power Flow Controller Using Modular Multilevel Converter--Part 3: Thyristor Bypass Switch

$41.00 $82.00 -50%
isbn 9781504471558
Product Code: IEEE 2745.3
Stock In Stock
Published: 10/20/2020
Number of Pages: 51
File Size: 1 file, 2.5 MB

Available Options

Product Description

IEEE Guide for Technology of Unified Power Flow Controller Using Modular Multilevel Converter--Part 3: Thyristor Bypass Switch

Introduction: This introduction is not part of IEEE Std 2745.3-2020, IEEE Guide for Technology of Unified Power Flow Controller Using Modular Multilevel Converter—Part 3: Thyristor Bypass Switch. As the most flexible, powerful, and comprehensive flexible ac transmission system (FACTS) device, the unified power flow controller (UPFC) can realize the bidirectional control of power flow, flexibly control voltage and reactive power, and improve the steady and dynamic stability of power grids. From the 1990s to 2004, three UPFC projects were put into operation: Inez substation of AEP, Kangjin substation of Korean Electric Power Corporation (KEPCO), and Marcy substation of New York Power Authority (NYPA), all of which utilized gate turn-off thyristor (GTO) devices and three-level converter technology. With the increasing development of power electronics equipment and technology, modular multilevel converter (MMC) technology with insulate-gate bipolar transistor (IGBT ) devices has been successfully applied to UPFCs, such as at the Tiebei substation of State Grid Corporation of China (SGCC), Yunzaobang substation of SGCC, and Mudu substation of SGCC. Compared to GTO devices and three-level converter technology, the MMC technology is superior in expandable structure, low output waveform deviation, easy control of capacitor voltage, and desirable fault tolerance of sub-modules. Therefore, the MMC technology is the development trend of UPFCs in the future. With the decreasing cost of converters, mor

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 1.3 Application
  • 1.4 Word usage
  • 3.1 Defi nitions
  • 3.2 Acronyms and abbreviations
  • 4.1 The necessity for fast bypass systems
  • 4.2 Main types of fast bypass systems
  • 4.3 Technical requirements for MBSs
  • 4.4 Coordination requirements
  • 7.1 General principles
  • 7.2 Performance requirements
  • 8.1 Condition monitoring for TBSs
  • 8.2 Trigger mechanism for TBSs
  • 8.3 Protection mechanism for TBSs
  • 9.1 Reliability improvement methods
  • 9.2 Reliability assessment for TBSs
  • 10.1 Summary of tests
  • 10.2 Production tests
  • 10.3 Dielectric tests
  • 10.4 Operational tests
  • 10.5 Commissioning test
  • 11.1 General
  • 11.2 Visual inspection of TBSs
  • 11.3 Maintenance test for TBSs
  • 12.1 Spares strategy
  • 12.2 Transfer preparation of spare parts
  • 12.3 Acceptance and transfer of spare parts
  • 12.4 Spare parts storage
  • 12.5 Spare parts accounting

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 2745.3-2020 PDF

IEEE 2745.3-2020 PDF

$41.00 $82.00