IEEE 487-2015 PDF

IEEE 487-2015 PDF

IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations

$85.50 $171.00 -50%
isbn 9781504406123
Product Code: IEEE 487
Stock In Stock
Published: 07/31/2015
Number of Pages: 106
File Size: 1 file, 6.4 MB

Available Options

Product Description

IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations

Introduction: This introduction is not part of IEEE Std 487™-2015, IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations—General Considerations. Telecommunications facilities serving electric supply locations often require special high-voltage protection (HVP) against the effects of fault-produced ground potential rise (GPR) or induced voltages, or both. Some of the telecommunications services are used for control and protective relaying purposes and may be called on to perform critical operations at times of power system faults. This requirement presents a major challenge in the design and protection of the telecommunications system because power system faults can result in the introduction of interfering voltages and currents into the telecommunications circuit at the very time when the circuit is most urgently required to perform its function. Even when critical services are not involved, special HVP may be required for both personnel safety and plant protection at times of power system faults. Effective protection of any telecommunications circuit requires coordinated protection on all circuits provided over the same telecommunications cable. Figure 24 provides an overview of a basic protection system. Some electrical environments, collectively called electric supply locations, require the application of unique electrical protection techniques because of their special nature. One such environment is the electric power station or subs

Contents:

  • 1.1 Background
  • 1.2 Scope
  • 1.3 Purpose
  • 1.4 Not covered
  • 3.1 Definitions
  • 3.2 Acronyms and abbreviations
  • 4.1 Overview
  • 4.2 Coupling
  • 4.3 Disturbances
  • 5.1 Electric power stations
  • 5.2 Typical grounding for sites immediately outside the grid
  • 5.3 Typical grounding at power line structures such as towers or poles
  • 5.4 Typical grounding requirements for base transceiver station (BTS)
  • 5.5 Step, touch, and mesh voltages for BTSs located on power line transmission or distribution
  • 5.6 Grounding for distributed antenna systems (DASs)
  • 7.1 Overview
  • 7.2 Service types
  • 7.3 SPO classifications
  • 7.4 Transmission considerations
  • 8.1 Overview
  • 8.2 Concepts and concerns
  • 8.3 Ownership
  • 8.4 General-use telecommunications cable in the electric supply location GPR ZOI
  • 8.5 Aerial cable installation
  • 8.6 Conduit containing metallic members or tracing medium
  • 9.1 Overview
  • 9.2 GPR plus induced voltage levels
  • 9.3 Basic protection system
  • 9.4 Protection configurations employing isolation devices
  • 9.5 General isolation protection configuration

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE 487-2015 PDF

IEEE 487-2015 PDF

$85.50 $171.00