IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage

$68.50 $137.00 -50%
isbn 9780738132464
Product Code: IEEE 95
Stock In Stock
Published: 04/12/2002
Number of Pages: 56
File Size: 1 file, 3 MB

Available Options

Product Description

IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage

Introduction: [This introduction is not part of IEEE Std 95-2002, IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage.] Traditionally, the insulation of rotating machines has been tested for dielectric strength with alternating volt- age. In 1952, attention was directed to testing with direct voltage. Since then, high direct voltage has been widely used. Many reports of procedure and results are found in the IEEE Transactions with expressions of widely differing opinion. In 1957, the Insulation Subcommittee of the IEEE Rotating Machinery Committee appointed a working group to review the existing literature and to prepare a guide for the conduct and interpretation of high direct-voltage insulation tests. It was found that many methods of making the tests have been used and that there was no uniform opinion of their relative merits. In 1971, the Insulation Subcommittee of the IEEE Rotating Machinery Committee appointed a working group to revise the existing guide to a recommended practice. In 1996, the Materials Subcommittee of the IEEE Electric Machinery Committee appointed a working group to revise the existing recommended practice. The document has been updated in a number of respects and typical test results using the ramped voltage test method have been included. At present there is wide usage of high direct voltage for insulation testing, but there are still areas of dis- agreement regarding the utility of such tests. In

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 1.3 Application and limitations
  • 4.1 Safety precautions required for high direct-voltage tests
  • 4.2 Influencing factors
  • 4.3 Gas-cooled machines
  • 4.4 Liquid-cooled machines
  • 4.5 Isolation of the winding from cables and auxiliary equipment
  • 4.6 Sectionalizing the winding
  • 5.1 High direct-voltage test equipment
  • 5.2 Discharge and grounding provisions
  • 5.3 High-voltage test connection to the winding
  • 5.4 Test connection to ground
  • 6.1 Test voltage for acceptance proof testing
  • 6.2 Test voltage for maintenance proof testing
  • 6.3 Voltage application
  • 6.4 Discharging and grounding
  • 6.5 Test results
  • 6.6 Insulation failure
  • 7.1 Test method
  • 7.2 Test setup
  • 7.3 Measured current
  • 7.4 Test voltage for controlled overvoltage testing
  • 7.5 Initial voltage level
  • 7.6 Voltage increments
  • 7.7 Discharging and grounding
  • 7.8 Test results
  • 7.9 Use of controlled overvoltage tests