IEEE Recommended Practice for Performing Temperature Rise Tests on Liquid-Immersed Power Transformers at Loads Beyond Nameplate Ratings

Introduction: This introduction is not part of IEEE Std C57.119-2018, IEEE Recommended Practice for Performing Temperature Rise Tests on Liquid-Immersed Power Transformers at Loads Beyond Nameplate Ratings. This introduction provides background related to the development of this recommended procedure. Additional information may be found in Annex B. Over the years, there has been a marked increase in the practice of loading transformers beyond their nameplate rating. In the past, many transformers were loaded beyond nameplate rating only during short time emergencies. Today, many users have established loading practices that subject transformers to loads beyond nameplate rating on a planned basis during periods of seasonal or daily peak loads, in addition to unexpected loads occurring during short or long time emergencies. Former ANSI standard C57.91 provided loading guidelines for distribution transformers, IEEE Std C57.92™- 1981 [B9] provided loading guidelines for power transformers rated 100 MVA and below, and IEEE Std C57.115™-1991 [B10] provided loading guidelines for transformers rated above 100 MVA.1 All of these documents have been combined into a revised IEEE Std C57.91™.2 These documents provide transformer loading guidelines based on judgment gained from years of experience of loading transformers. However, prior to this document, no standard test procedure existed to evaluate the consequences of loading a transformer at loads beyond nameplate rating. Investigations carried out

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 3.1 Defi nitions
  • 3.2 Symbols
  • 3.3 Subscripts
  • 4.1 Preliminary evaluation
  • 4.2 Cooling equipment operation
  • 5.1 Thermal degradation
  • 5.2 Other factors limiting loading
  • 5.3 Monitoring of test results
  • 5.4 Maximum temperatures
  • 6.1 Ambient air temperature
  • 6.2 Insulating liquid temperatures
  • 6.3 Other temperatures
  • 6.4 Currents
  • 7.1 Losses
  • 7.2 Temperature indicator readings
  • 7.3 Tank surface and other temperatures
  • 7.4 Insulating liquid levels
  • 9.1 Tap position and connection
  • 9.2 Number of tests
  • 9.3 Applied test currents
  • 9.4 Discontinued tests
  • 9.5 Temperature rise test at rated load
  • 9.6 Temperature rise test at reduced load
  • 9.7 Temperature rise test at load beyond nameplate rating
  • 9.8 Evaluation of thermal data
  • 9.9 Evaluation of other data
  • 10.1 Recommended prior tests
  • 10.2 Information specifi ed by user