IEEE C57.159-2016 PDF

IEEE C57.159-2016 PDF

IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems

$35.50 $71.00 -50%
isbn 9781504422666
Product Code: IEEE C57.159
Stock In Stock
Published: 11/03/2016
Number of Pages: 33
File Size: 1 file, 3.1 MB

Available Options

Product Description

IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems

Introduction: This introduction is not part of IEEE Std C57.159-2016, IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems. Transformers addressed in this guide are for the application in distributed photovoltaic (DPV) power gen- eration systems and generally belong to Class I transformers per IEEE Std C57.12.00 and Category I and II transformers per IEEE Std C57.12.00 and IEEE Std C57.12.01. The guide focuses mainly on the inverter transformers of the DPV power generation systems that are connected to the inverters supplying ac voltage and current to the primary (LV) winding of the transformer. Presently known nominal voltage of these transformers is up to 36 kV and rated power is up to 4000 kVA. Transformers for DPV systems are gradually increasing in their numbers in the field due to the recent in- creased focus on renewable energy sources. These transformers are primarily used as step-up transformers but can be used as step-down transformers as well. Transformers for DPV systems have a number of specific issues (requirements and constraints) that affect transformer design and application. This IEEE guide provides information to support specification, design, and application of these transformers by: Explaining concerns and differences of DPV system application and providing specific operation and construction techniques to address these concerns and differences. Summarizing these considerations for the engineer specifying the transformer

Contents:

  • 1.1 Scope
  • 1.2 Purpose
  • 4.1 Typical DPV power generation systems and DPV system inverter transformers
  • 4.2 Ambient temperature, weather, and mode of operation—Effect on the system, inverter, and
  • 4.3 Technical specifi cs of the DPV power generation systems
  • 5.1 General design considerations and recommendations
  • 5.2 Loading, loss evaluation, and effi ciency
  • 5.3 Power quality consideration
  • 5.4 Voltage and insulation coordination
  • 5.5 Other design consideration
  • 5.6 Technical requirements of auxiliary transformers
  • 6.1 Transformer type
  • 6.2 Design consideration
  • 6.3 Construction consideration
  • 6.4 Recommended accessories and gauges placement
  • 6.5 Arc fl ash aspects and protection
  • 7.1 Testing
  • 7.2 Installation and commissioning

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEEE C57.159-2016 PDF

IEEE C57.159-2016 PDF

$35.50 $71.00