ISO 10497-2022 PDF

ISO 10497-2022 PDF

Testing of valves-Fire type-testing requirements

$71.50 $143.00 -50%
Product Code: ISO 10497
Stock In Stock
Edition: 4.
Published: 10/2022
Number of Pages: 26
File Size: 1 file, 2 Bytes

Available Options

Product Description

Testing of valves — Fire type-testing requirements

Introduction: This document covers the requirements and method for evaluating the performance of valves when they are exposed to specified fire conditions. The performance requirements establish limits of acceptability of a valve, regardless of size, material or pressure rating. The burn period has been established to represent the maximum time required to extinguish most fires. Fires of longer duration are considered to be of major magnitude, with consequences greater than those anticipated in the test. The test pressure during the burn is set at 0,2 MPa (2 bar) for soft-seated valves rated PN 10, PN 16, PN 25 and PN 40, Class 150 and Class 300, to better simulate the conditions that would be expected in a process plant when a fire is detected, and pumps are shut down. In this case, the source of pressure in the system is the hydrostatic head resulting from liquid levels in towers and vessels. This situation is approximated by this lower test pressure. In production facilities, valves are typically of a higher rating and the pressure source is not easily reduced when a fire is detected. Therefore, for all other valves, the test pressure during the burn is set at a higher value to better simulate the expected service conditions in these facilities. Use of this document assumes that the execution of its provisions is entrusted to appropriately qualified and experienced personnel, because it calls for procedures that can be injurious to health, if adequate precautions are not taken. This doc

Scope: This document specifies fire type-testing requirements and a fire type-test method for soft- and metal- seated isolation valves with one or more obturators. It is not applicable to the testing requirements for valve actuators other than manually operated gearboxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of this document. This document specifies the measurement and assessment criteria for: a) through-seat leakage; b) external leakage; c) cavity overpressure relief of double-seated valves; d) operability. This document specifies the rules whereby the fire-type testing qualification for a valve can be extended to untested sizes, pressure ratings and materials of construction of the same basic design type. Fire test reports of valves tested according to previous editions of this document are acceptable when submitted together with the full and compliant fire test report as per 6.7 of the edition under which it was tested. Any data missing as required from 6.7 within the fire test report are accepted or rejected at the purchaser’s discretion. NOTE For the purposes of this document, the terms “fire type-test” and “fire test” are synonymous.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 10497-2022 PDF

ISO 10497-2022 PDF

$71.50 $143.00