Measurement of fluid flow in closed conduits - Guidance to the selection, installation and use of Coriolis flowmeters (mass flow, density and volume flow measurements)

$129.00 $258.00 -50%
Product Code: ISO 10790
Stock In Stock
Edition: 3RD
Published: 04/01/2015
Number of Pages: 44
File Size: 1 file, 1 Byte

Available Options

Product Description

Measurement of fluid flow in closed conduits - Guidance to the selection, installation and use of Coriolis flowmeters (mass flow, density and volume flow measurements)

Introduction: This International Standard has been prepared as a guide for those concerned with the selection, testing, inspection, operation, and calibration of Coriolis flowmeters (Coriolis flowmeter assemblies). A list of related International Standards is in the Bibliography. This International Standard provides the following: a) description of the Coriolis operating principle; b) guideline to expected performance characteristics of Coriolis flowmeters; c) description of calibration, verification, and checking procedures; d) description of potential error sources; e) common set of terminology, symbols, definitions, and specifications. The next paragraphs contain an explanation of when to use the measurement terminology, uncertainty, and accuracy. The VIM definition (see 3.2) of accuracy: closeness of agreement between a measured quantity value and a “true quantity value” of a measurand. Per the VIM, accuracy is a quality and should not be given a numerical value. To understand the preceding paragraph, one needs to understand that a “true quantity value” does not exist. The best that can be done is to determine the measured quantity value with measurement instrumentation calibrated with a very good but imperfect reference. Therefore, the measurement is an estimate. Uncertainty is used to define these measurement estimates (see 3.2.2). Many Coriolis manufacturers use accuracy and zero stability as part of their published performance specifications. The manufacturer’s accuracy specificati

Scope: This International Standard gives guidelines for the selection, installation, calibration, performance, and operation of Coriolis flowmeters for the measurement of mass flow and density. This International Standard also gives appropriate considerations regarding the type of fluids measured, as well as guidance in the determination of volume flow and other related fluid parameters. NOTE Fluids defined as air, natural gas, water, oil, LPG, LNG, manufactured gases, mixtures, slurries, etc.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 10790-2015 PDF

ISO 10790-2015 PDF

$129.00 $258.00