ISO 10993-17-2023 PDF

ISO 10993-17-2023 PDF

Biological evaluation of medical devices-Part 17: Toxicological risk assessment of medical device constituents

$13.00 $26.00 -50%
Product Code: ISO 10993-17
Stock In Stock
Edition: 2.
Published: 09/2023
Number of Pages: 72
File Size: 1 file, 3 Bytes

Available Options

Product Description

Biological evaluation of medical devices — Part 17: Toxicological risk assessment of medical device constituents

Introduction: A medical device or material that has direct or indirect contact with the patient's body or the user’s body is expected to perform its intended use while being free from unacceptable risks, including biological and toxicological risks. For this reason, medical devices are typically subject to a biological evaluation within a risk management process to assess their safety. The ISO 10993 series specifies a process through which the manufacturer of a medical device can identify biological hazards associated with the medical device, estimate and evaluate the risks associated with these hazards, control these risks, and monitor the effectiveness of the controls throughout the life cycle of the medical device. ISO 10993-1, in line with ISO 14971, facilitates a common understanding of biological evaluation within a risk management process. ISO 10993-18 includes methods for identifying and quantifying hazardous medical device constituents so that their toxicological risk can be evaluated. Furthermore, ISO 10993-18 specifies when to consider conducting a toxicological risk assessment per this document. This document specifies requirements for a toxicological risk assessment process for specific medical device constituents that is used within the biological evaluation process specified by ISO 10993-1 and Clause 1. For example, the biological risk analysis of a medical device includes obtaining constituent information as described in ISO 10993-1:2018, 6.2 and ISO 10993-18. The extent to

Scope: This document specifies the process and requirements for the toxicological risk assessment of medical device constituents. The methods and criteria used to assess whether exposure to a constituent is without appreciable harm are also specified. The toxicological risk assessment can be part of the biological evaluation of the final product, as described in ISO 10993-1. The process described in this document applies to chemical characterization information obtained in line with ISO 10993-18. When a toxicological risk assessment of either the compositional information or analytical chemistry data (e.g. extractable data or leachable data) are required to determine whether the toxicological risks related to the constituents are negligible or tolerable. The process described in this document is not intended to apply to circumstances where the toxicological risk has been estimated by other means, such as: — constituents, excluding cohort of concern or excluded chemicals, that are present in or extracted from a medical device at an amount representative of patient exposure below a relevant, toxicologically- based reporting threshold (see applicable requirements in ISO 10993-18:2020, Annex E and ISO/TS 21726); — a new or changed medical device for which chemical or biological equivalence has been established with an existing biocompatible or clinically established medical device (see applicable requirements in ISO 10993-18:2020, Annex C). The process described in this document is also not applicable to: — medical device constituents that do not contact the body (e.g. in vitro diagnostics); — biological risks associated with physical interactions of the medical device with the body (i.e. application of mechanical forces, energy or surface morphology, etc.), provided that the chemical exposure is not changed; — active pharmaceutical ingredients of device-drug combination products or biologic components of device-biologic combination products as additional regulatory considerations can apply; — exposure to a particular constituent that arises from sources other than the device, such as food, water or air.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 10993-17-2023 PDF

ISO 10993-17-2023 PDF

$13.00 $26.00