ISO 10993-9-2019 PDF

ISO 10993-9-2019 PDF

Biological evaluation of medical devices-Part 9: Framework for identification and quantification of potential degradation products

$60.00 $120.00 -50%
Product Code: ISO 10993-9
Stock In Stock
Edition: 3RD
Published: 11/2019
Number of Pages: 18
File Size: 1 file, 1 Byte

Available Options

Product Description

Biological Evaluation of Medical Devices - Part 9: Framework for Identification and Quantification of Potential Degradation Products

Introduction: This document is intended to present the general principles on which the specific material investigations to identify and quantify degradation products described in ISO 10993-13 (polymers), ISO 10993-14 (ceramics) and ISO 10993-15 (metals and alloys) are based. Information obtained from these studies is intended to be used in the biological evaluations described in the remaining parts of ISO 10993. The materials used to construct medical devices can form degradation products when exposed to the biological environment, and in the body these products might behave differently to the bulk material. Mechanical wear, which is not in scope of this document, causes mostly particulate debris, whereas non- mechanical degradation can lead to the release of free ions or to different kinds of reaction products in the form of organic or inorganic compounds. The degradation products can be either reactive or stable and without biochemical reaction with their environment. Accumulations of substantial quantities of stable degradation products can, however, have physical effects on the surrounding tissues. Degradation products might remain at the location of their generation or might be transported within the biological environment by various mechanisms. The level of biological tolerability of degradation products depends on their nature and concentration, and should be primarily assessed through clinical experience and focused studies. For theoretically possible, new and/or unknown degradatio

Scope: This document provides general principles for the systematic evaluation of the potential and observed degradation of medical devices through the design and performance of in vitro degradation studies. Information obtained from these studies can be used in the biological evaluation described in the ISO 10993 series. This document is applicable to both materials designed to degrade in the body as well as materials that are not intended to degrade. This document is not applicable to: a) the evaluation of degradation which occurs by purely mechanical processes; methodologies for the production of this type of degradation product are described in specific product standards, where available; NOTE Purely mechanical degradation causes mostly particulate matter. Although this is excluded from the scope of this document, such degradation products can evoke a biological response and can undergo biological evaluation as described in other parts of ISO 10993. b) leachable components which are not degradation products; c) medical devices or components that do not contact the patient's body directly or indirectly.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 10993-9-2019 PDF

ISO 10993-9-2019 PDF

$60.00 $120.00