Plastics piping systems for renovation of underground water supply networks — Part 4: Lining with cured-in-place pipes
Introduction: This document is a part of a system standard for plastics piping systems of various materials used for renovation of existing pipelines in a specified application area. System standards for renovation dealing with the following applications are either available or under preparation: — the ISO 11296 series, Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks; — the ISO 11297 series, Plastics piping systems for renovation of underground drainage and sewerage networks under pressure; — the ISO 11298 series, Plastics piping systems for renovation of underground water supply networks (including this document); — the ISO 11299 series, Plastics piping systems for renovation of underground gas supply networks. These system standards are distinguished from those for conventionally installed plastics piping systems by the requirement to verify certain characteristics in the “as-installed” condition, after site processing. This is in addition to specifying requirements for plastics piping systems components “as manufactured”. Each of the system standards comprises a: — Part 1: General and all applicable renovation technique family-related parts, which for water supply networks include or potentially include the following: — Part 2: Lining with continuous pipes; — Part 3: Lining with close-fit pipes; — Part 4: Lining with cured-in-place pipes (this document); — Part 5: Lining with discrete pipes; — Part 6: Lining with adhesive-backed hoses; —
Scope: This document, in conjunction with ISO 11298-1, specifies requirements and test methods for cured- in-place pipes and fittings used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines. It applies to independent (fully structural, class A) and interactive (semi structural, class B) pressure pipe liners, as defined in ISO 11295, which do not rely on adhesion to the existing pipeline. It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials, reinforcement, and other process-related plastics components (see 5.1). It does not include requirements or test methods for resistance to cyclic loading or the pressure rating of CIPP liners where passing through bends, which are outside the scope of this document. It is applicable to cured-in-place pipe lining systems intended to be used at a service temperature of up to 25 °C. NOTE For applications operating at service temperatures greater than 25 °C, guidance on re-rating factors can be supplied by the system supplier.