Émissions de sources fixes - Détermination d'une faible concentration en masse de matières particulaires (poussières) - Méthode gravimétrique manuelle
Introduction: The measurement method specified in this document has been developed in close liaison and cooperation between ISO/TC 146/SC 1 and CEN/TC 264, resulting in the preparation of the first editions of the International Standard ISO 12141:2002 and the European Standard EN 13284-1:2001. In the meantime, CEN/TC 264 has revised EN 13284-1:2001 in order to adapt the content to the state of the art. The basic concept of the measurement method has not been changed. Against this background and to ensure comparability of measurement results at international level, ISO/TC 146/SC 1 has decided to adopt EN 13284-1:2017 without technical changes. However, some editorial adjustments have been made to take account of the international application of this document. For example, references to EN 15259:2007 in EN 13284-1:2017 have been replaced in this document by references to the technically identical ISO 15259:2023. To meet the specifications of this document, a certain level of accuracy for weighing the particle sample is needed. At low dust concentrations, this level of accuracy can be achieved by: a) exercising extreme care in weighing, as per procedures of this document; b) extending the sampling time at conventional sampling rates; or c) sampling at higher rates for conventional sampling times (high-volume sampling). High-volume sampling is not part of this document since it was not part of the validation of the measurement method. The measurement method specified in this document can be us
Scope: This document specifies the standard reference method (SRM) for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m3 at standard conditions. This document is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it can be applied to gases emitted from other stationary sources, and to higher concentrations. If the gases contain unstable, reactive or semi-volatile substances, the measurement depends on the sampling and filter treatment conditions. This method has been validated in field tests with special emphasis to dust concentrations around 5 mg/m3. The results of the field tests are presented in Annex A.