ISO 13004-2022 PDF

ISO 13004-2022 PDF

Sterilization of health care products-Radiation-Substantiation of selected sterilization dose: Method VDmax SD

$145.50 $291.00 -50%
Product Code: ISO 13004
Stock In Stock
Edition: 1.
Published: 10/2022
Number of Pages: 62
File Size: 1 file, 1 Byte

Available Options

Product Description

Sterilization of health care products — Radiation — Substantiation of selected sterilization dose: Method VDmax SD

Introduction: This document is intended to be used in conjunction with ISO 11137-1. One of the activities encompassed within process definition in ISO 11137-1 is the option to select and substantiate a sterilization dose to be applied to health care products. ISO 11137-2 includes Method VDmaxSD for the substantiation of 25 kGy as a sterilization dose (termed Method VDmax25) for product with an average bioburden less than or equal to 1 000 and Method VDmax15 for the substantiation of 15 kGy as a sterilization dose for product with an average bioburden less than or equal to 1,5. This document extends the methods of selection and substantiation of a sterilization dose specified in ISO 11137-2. It provides a methodology for the substantiation of selected sterilization doses of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy and 35 kGy, each of which is valid only for a specified upper limit of average bioburden. NOTE Selected sterilization doses of 25 kGy and 15 kGy are not included in this document. The seven methods in this document follow the same technical steps as the methods given in ISO 11137-2 for selection and substantiation of sterilization doses of 25 kGy and 15 kGy. However, the descriptive text in this document has been modified to better communicate the methods and hence the text occasionally differs from that in ISO 11137-2. The method described in this document is for substantiation of a selected sterilization dose to achieve a sterility assurance level (SAL) of 10−6 or

Scope: This document describes a method for substantiating a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy that achieves a sterility assurance level (SAL) of 10−6 or less for radiation sterilization of health care products. This document also specifies a method of sterilization dose audit used to demonstrate the continued effectiveness of the substantiated sterilization dose. NOTE 1 Selection and substantiation of the sterilization dose is used to meet the requirements for establishing the sterilization dose within process definition in ISO 11137-1. This document does not apply to other sterilization doses than the substantiation of a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy. The method is not used for the substantiation of a selected sterilization dose if the average bioburden of the entire product item exceeds the limit specified for the selected sterilization dose (see Table 3). NOTE 2 The methods for substantiation of selected sterilization doses of 25 kGy and 15 kGy are not included in this document. They are described in ISO 11137-2. If the decision is made to use this method of sterilization dose establishment, the method is intended to be followed in accordance with the requirements (shall) and guidance (should) stipulated herein.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 13004-2022 PDF

ISO 13004-2022 PDF

$145.50 $291.00