Optics and photonics — Lasers and laser-related equipment — Cavity ring-down method for high-reflectance and high-transmittance measurements
Introduction: With the development of film-deposition technology, the performance of optical thin films, especially the highly reflective (HR) and highly anti-reflective (AR) coatings which are widely used in large high-power laser systems, interferometric gravitational-wave detectors, laser gyroscopes, and cavity-enhanced and cavity ring-down spectroscopy applications, has been substantially improved in recent years. Laser-based optical systems require some optical components with extremely high reflectance or transmittance characteristic. It is necessary to be able to measure this reflectance or transmittance characteristic precisely. Up to now, the ISO standardized testing methods for reflectance/transmittance of optical laser components have the accuracy limit of approximately 0,01 % (for measurement of absolute reflectance/transmittance), which are not appropriate for measuring the reflectance /transmittance higher than 99,99 %, or in some cases measurement accuracy better than 0,01 % is required. The measurement procedures in this document have been optimized to allow the measurement of high reflectance or transmittance (larger than 99 %, theoretically up to 100 %) of optical laser components using the cavity ring-down technique which provides reflectance or transmittance data with high accuracy, high repeatability and reproducibility, and high reliability. © ISO 2021 – All rights reserved
Scope: This document specifies measurement procedures for the precise determination of the high reflectance or high transmittance (>99 %) of optical laser components. The methods given in this document are intended to be used for the testing and characterization of high reflectance of both concave and plane mirrors or high transmittance of plane windows used in laser systems and laser-based instruments. The reflectance of convex mirrors or transmittance of positive or negative lenses can also be tested by taking into consideration the radius of curvature of the mirror surface or the focal length of the lens. This document is complementary to ISO 15368 which specifies the measurement procedures for the determination of reflectance and transmittance of optical components with spectrophotometry. ISO 15368 is applicable to the measurements of reflectance and transmittance in the range from 0 % to 100 % with a typical accuracy of ±0,3 %, and is therefore not applicable to the precise measurements of reflectance and transmittance higher than 99,9 %.