ISO 13322-1-2014 PDF

ISO 13322-1-2014 PDF

Particle size analysis - Image analysis methods - Part 1: Static image analysis methods

$96.50 $193.00 -50%
Product Code: ISO 13322-1
Stock In Stock
Edition: 2ND
Published: 05/15/2014
Number of Pages: 32
File Size: 1 file, 646 Bytes

Available Options

Product Description

Particle size analysis - Image analysis methods - Part 1: Static image analysis methods

Introduction: The purpose of this part of ISO 13322 is to give guidance when using images for particle size analysis. Image analysis is a technique that has gained popularity in different applications. The aim of this part of ISO 13322 is to give a standardized description of the technique used and its validation. This part of ISO 13322 does not describe specific instruments and is restricted to those parts of the acquisition of images that are relevant to the accuracy of the particle size analysis. This part of ISO 13322 includes methods of calibration verification and recommends using a certified standard as a reference scale. However it is sensible to make some measurements on particles under study, or other reference objects, of known size so that the likely systematic uncertainties introduced by the equipment can be assessed. Errors introduced at all stages of the analysis from sub-division of the sample to generation of the final result add to the total uncertainty of measurements and it is important to obtain estimates for the uncertainty arising from each stage. Essential operations are identified to ensure that measurements made conform to this part of ISO 13322 and are traceable. © ISO 2014 – All rights reserved

Scope: This part of ISO 13322 is applicable to the analysis of images for the purpose of determining particle size distributions where the velocity of the particles against the axis of the optical system of the imaging device is zero. The particles are appropriately dispersed and fixed in the object plane of the instrument. The field of view may sample the object plane dynamically either by moving the sample support or the camera provided this can be accomplished without any motion effects on the image. Captured images can be analysed subsequently. This part of ISO 13322 concentrates upon the analysis of digital images created from either light or electron detection systems. It does not address the method of creating the image although the detection settings chosen together with its calibration are important to particle sizing accuracy. This part of ISO 13322 considers only image evaluation methods using complete pixel counts. Both the type of distribution, (by number or by volume) together with the width of the particle size distribution has a very material influence upon the number of particles to be measured to secure the desired accuracy within the specified confidence limits. An example is shown in Annex A. Automation of the analysis is possible in order to measure sufficient particle numbers for a required degree of precision. This part of ISO 13322 does not address the sample preparation. However, the sub sampling, dispersion and presentation of particles to be measured are a vital part of the operational chain of actions necessary to ensure accuracy and precision of any final result. NOTE Further details about sampling and sample preparation can be found in ISO 14887 and ISO 14488.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 13322-1-2014 PDF

ISO 13322-1-2014 PDF

$96.50 $193.00