Fans — Determination of fan sound power levels under standardized laboratory conditions — Part 2: Reverberant room method
Introduction: This document deals with the determination of the fan sound power level appropriate to a particular application. In describing the test and rating procedures, numerous references are made to ISO 5801 as well as to other relevant ISO standards. This reverberant room method should be read in conjunction with ISO 13447-1 and each part of the ISO 13347 series which details other methods for determining the sound power radiated by a fan in specified installation conditions as a function of frequency. The method in this document employs standard sound measurement instrumentation. The test set-ups are generally designed to represent the physical orientation of a fan as installed, in accordance with ISO 5801 or ISO 13350. This document primarily deals with the determination of sound power levels of fans used for ducted applications. The test procedures described in this document relate to laboratory conditions. The measurement of performance under site conditions is not included. Acoustic system effects can be considerable where the airflow into and out of the fan is not free from swirl, nor the velocity profile there fully developed. This document describes methods for determining sound power levels of fans in one-third octave bandwidths and one octave bandwidths. Data obtained in accordance with this document may be used for the following purposes amongst others: a) comparison of fans which are similar in size and type; b) comparison of fans which are different in size and type; c)
Scope: This document specifies determining sound power levels of fans under standardized laboratory conditions from sound pressure levels measured in a reverberant room. This document is applicable for determination of the acoustic performance of fans. This document can additionally be applied to determine the acoustic performance of fans combined with an ancillary device, such as a roof cowl or damper or, where the fan is fitted with a silencer, the sound power resulting from the fan and silencer combination. For guidance of testing with ancillary items, see Annex C. This document applies to fans as defined in ISO 13349-1. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined. This document is intended to be used in conjunction with ISO 5136, which covers the in-duct method, and ISO 10302-1 for small fans. The size of fans which can be tested in accordance with this document is limited only by the practical aspects of the test set-up. Test fan dimensions and air performance will control the room size. NOTE Based on usage, small fans can be tested according to this document or to ISO 10302-1. For reverberant field tests, the size of equipment under test is limited to less than 2 % of the room volume. For low power fans (up to 3 kW) that can be run from a domestic power supply (single phase AC at a voltage not exceeding 250 V and a current not exceeding 16 A), reference IEC 60704-2-7[18]. The test arrangements in this document establish the laboratory conditions necessary for a successful test. It is difficult to meet these requirements in situ and this document is not intended for field measurements. In these situations, users are reminded that the acoustic environment is unlikely to meet the specified conditions and there can be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.