ISO 13348-2025 PDF

ISO 13348-2025 PDF

Fans-Tolerances, methods of conversion and technical data presentation

$60.00 $120.00 -50%
Product Code: ISO 13348
Stock In Stock
Edition: 3.
Published: 06/2025
Number of Pages: 84
File Size: 1 file, 6 Bytes

Available Options

Product Description

Industrial fans Tolerances, methods of conversion and technical data presentation

Introduction: This document aims to clarify technical aspects of contracts where fan performance is concerned, and the accuracy and consistency of performance details published in technical catalogues. In this document, a distinction is drawn between specially designed fans to suit a specific purpose, to meet a contract specification, and series-produced fans where the performance data is contained in a catalogue. For purpose-designed fans, the methods of calculating performance data under contract conditions, from performance data obtained under test conditions, are described in Clause 5 for both air and sound data. Four tolerance grades are given, each appropriate to a particular type of fan and/or its application. These procedures have been found satisfactory; however, the supplier and user can agree to adopt alternative methods. For series-produced non-certified fans, the associated technical data will be contained in a catalogue (electronic and/or printed form). In this case, the recommended method of applying tolerances is as described in Clause 5. For series-produced fans in certified ratings programmes, the associated technical data will be contained in a catalogue (electronic and/or printed form). In this case, the recommended method of applying tolerances is as described in Clause 6 (based on AMCA (Air Movement and Control Association) International, Inc. certified reference program rules[16],[17],[18]). © ISO 2025 – All rights reserved

Scope: This document specifies performance tolerances and the technical data presentation for fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used for household or similar purposes (ceiling and table fans, extractor fans, etc.). For jet fans, refer to ISO 13350. The upper limit of fan work per unit mass is normally 25 kJ/kg, corresponding to an increase of fan pressure of approximately 30 kPa for a mean density in the fan of 1,2 kg/m3. For higher values, agreement is to be reached between the supplier and the user. This document applies the five installation categories defined in ISO 5801: free inlet, free outlet; free inlet, ducted outlet; ducted inlet, free outlet; ducted inlet, ducted outlet; free inlet and free outlet without a partition. The performance of a fan can vary considerably with the installation category it is operating within. Therefore, these categories form an important part of the definition of the fan’s technical data presentation. NOTE International acceptance of the five installation categories provides the opportunity to base a contract on the most appropriate fan category for the end user and the system designer. Correspondingly, the likelihood of the fan providing the agreed performance, without compromise or concession, is enhanced. The efficiency scaling procedures described in 8.1.5 apply to centrifugal fans and axial fans within the specific speed ranges shown in Table 4. To date, there is no experimental data to confirm how they apply to mixed flow fans, having specific speeds in between. Category E fans are treated in Clause 7.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 13348-2025 PDF

ISO 13348-2025 PDF

$60.00 $120.00