Determination of flash point — Abel closed-cup method
Introduction: Flash point values are used in shipping, storage, handling and safety regulations, as a classification property to define “flammable” and “combustible” materials. Precise definition of the classes is given in each particular regulation. A flash point value can indicate the presence of highly volatile material(s) in a relatively non-volatile or non-flammable material, and flash point testing can be a preliminary step to other investigations into the composition of unknown materials. Flash point determinations are not appropriate for potentially unstable, decomposable, or explosive materials, unless previously established that heating the specified quantity of such materials in contact with the metallic components of the flash point apparatus, within the temperature range required for the method, does not induce decomposition, explosion or other adverse effects. Flash point values are not a constant physical-chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can therefore be defined only in terms of a standard test method, and no general valid correlation can be guaranteed between results obtained by different test methods or with test apparatus different from that specified. ISO/TR 29662[7] gives useful advice on carrying out flash point tests and interpreting results. © ISO 2021 – All rights reserved
Scope: This document specifies a method for the determination of the manual and automated closed cup flash point of combustible liquids having flash points between –30,0 °C to 75,0 °C. However, the precision given for this method is only valid for flash points in the range −8,5 °C to 75,0 °C. This document is not applicable to water-borne paints. NOTE 1 Water borne paints can be tested using ISO 3679[1]. NOTE 2 See 9.1 for the importance of this test in avoiding loss of volatile materials. NOTE 3 Liquids containing halogenated compounds can give anomalous results. NOTE 4 The thermometer specified for the manual apparatus limits the upper test temperature to 70,0 °C. NOTE 5 See 13.1 for more specific information related to precision.