Aerospace series - Hydraulic filter elements - Test methods - Part 2: Conditioning
Introduction: In aerospace hydraulic fluid power systems, power is transmitted and controlled through a liquid under pressure. The liquid is both a lubricant and power-transmitting medium. The presence of solid contaminant particles in the liquid interferes with the ability of the hydraulic fluid to lubricate and causes wear and malfunction of the components. The extent of contamination in the fluid has a direct bearing on the performance, reliability, and safety of the system, and needs to be controlled to levels that are considered appropriate for the system concerned. Different principles are used to control the contamination level of the fluid by removing solid contaminant particles; one of them uses a filter element enclosed in a filter housing. The filter element is the porous device that performs the actual process of filtration. The complete assembly is designated as a filter. Filter elements are designed to withstand a range of thermal stresses, such as low and high temperature extremes, and system demands at low temperature (cold starts) whereby hydraulic fluid passes through the element at a greatly increased viscosity. These thermal stresses test both the chemical and thermal stability of the filter element. These cold starts test the ability of the filter element to withstand the high differential pressures and potential weakness at low temperatures without subsequent loss of integrity or performance. These stresses will be encountered within the lifetime of any filter element
Scope: This part of ISO 14085 specifies — a procedure to thermally condition a hydraulic filter element to presumed aerospace hydraulic system stresses, — a test procedure to complete cold soaks, hot soaks, and temperature variation in a combined manner, and — a test procedure to simulate cold starts. This part of ISO 14085 is not intended to qualify a filter element under replicate conditions of service; this can only be done by a specific test protocol developed for the purpose, including actual conditions of use, for example the operating fluid or contamination. This part of ISO 14085 is intended to provide a test procedure that yields reproducible thermal test conditioning of a hydraulic filter element, for simulation of the thermal stresses typically encountered in an aerospace hydraulic system. The conditioning test procedures defined in this part of ISO 14085 are intended to be used prior to performance tests as specified in other parts of this International Standard. The tests data resulting from application of this part of ISO 14085 can be used to compare the performance of aerospace hydraulic filter elements.