ISO 14630-2024 PDF

ISO 14630-2024 PDF

Non-active surgical implants-General requirements

$96.50 $193.00 -50%
Product Code: ISO 14630
Stock In Stock
Edition: 5.
Published: 09/2024
Number of Pages: 28
File Size: 1 file, 1 Byte

Available Options

Product Description

Non-active surgical implants — General requirements

Introduction: There are three levels of standards dealing with non-active surgical implants and related instrumentation. For the implants themselves, they are as follows, with Level 1 being the highest: Level 1: general requirements for non-active surgical implants; Level 2: particular requirements for families of non-active surgical implants; Level 3: specific requirements for types of non-active surgical implants. Level 1 standards include this document which contains requirements that apply to all non-active surgical implants, and ISO 16061, which contains requirement for instruments associated with non-active surgical implants. They also anticipate that there are additional requirements in the Level 2 and Level 3 standards. Level 2 standards (see References [2], [12], [23], [27] and [42]) apply to a more restricted set or family of non-active surgical implants, such as those designed for use in neurosurgery, cardiovascular surgery or joint replacement. Level 3 standards (see References [3], [13], [24] and [25]) apply to specific types of implants within a family of non-active surgical implants, such as hip joints or arterial stents. To address the requirements for a specific implant, all related Level 1, 2 and 3 standards should be applied. © ISO 2024 – All rights reserved

Scope: This document specifies general requirements for non-active surgical implants, hereafter referred to as implants. This document is not applicable to dental implants, dental restorative materials, transendodontic and transradicular implants, intra-ocular lenses and implants utilizing viable animal or human tissue. With regard to safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging and information supplied by the manufacturer, and tests to demonstrate compliance with these requirements. Additional requirements applicable to specific implants or implant families are given or referred to in Level 2 and Level 3 standards. NOTE 1 This document does not require that the manufacturer have a quality management system in place. However, many regulatory authorities require the application of a quality management system, such as that described in ISO 13485, to ensure that the implant achieves its intended performance and safety. NOTE 2 In this document, when not otherwise specified, the term "implant" refers to each individual component of a system or a modular implant, provided separately or as a set of components, as well as to all ancillary implants or associated implants designed for improving the intended performance.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 14630-2024 PDF

ISO 14630-2024 PDF

$96.50 $193.00