ISO 15382-2025 PDF

ISO 15382-2025 PDF

Radiological protection-Procedures for monitoring the dose to the lens of the eye, the skin and the extremities

$113.50 $227.00 -50%
Product Code: ISO 15382
Stock In Stock
Edition: 3.
Published: 08/2025
Number of Pages: 42
File Size: 1 file, 3 Bytes

Available Options

Product Description

Radiological protection — Procedures for monitoring the dose to the lens of the eye, the skin and the extremities

Introduction: The human body shall be protected from harmful effects of exposure to ionizing radiation, internally and externally. Effective dose limits keep the occurrence of stochastic effects to an “acceptable” level, while protection from tissue reactions (i.e. deterministic effects) is provided by dose limits for specific organs. The human skin shall be protected from external tissue reactions, such as erythema and ulceration. For the lens of the eye, there is the risk of radiation induced cataract at elevated exposures. To protect the skin of the whole body, the extremities, and the lens of the eye, separate dose limits are recommended by the International Commission on Radiological Protection (ICRP). These separate dose limits are needed because, in case of localized exposures, the equivalent doses to the skin and the lens of the eye could exceed these limits even if the effective doses were lower than the limit. Specific dosimetry is needed to monitor these doses and to assess compliance with applicable limits. There are some situations where the correct assessment of the exposure of the skin, extremities, and lens of the eye can be challenging. In the nuclear sector, there can be exposure due to weakly penetrating radiation caused by unshielded unsealed radioactive sources, or by working in glove boxes. These types of exposure can occur, in particular in connection with contamination. Exposure to weakly penetrating radiation from radioactive noble gases in room air also shall be c

Scope: This document provides procedures for monitoring the dose to the skin, the extremities, and the lens of the eye. It gives guidance on how to decide if such dosemeters are needed and to ensure that individual monitoring is appropriate to the nature of the exposure, taking practical considerations into account. This document specifies procedures for individual monitoring of radiation exposure of the skin of the body, extremities (skin of the hands, fingers, wrists, forearms including elbow, lower leg including patella, feet and ankles), and lens of the eye in planned exposure situations. It covers practices which involve a risk of exposure to photons in the range of 8 keV to 10 MeV, electrons and positrons in the range of 0,07 MeV to 1,2 MeV mean beta energies being equivalent to 0,22 MeV and 3,6 MeV beta maximum energy - in accordance to the ISO 6980 series, and neutrons in the range of thermal to 20 MeV. This document gives guidance for the design of a monitoring programme to ensure compliance with legal individual dose limits. It refers to the appropriate operational dose quantities, and it gives guidance on the type and frequency of individual monitoring and the type and positioning of the dosemeter. Finally, different approaches to assess and analyse skin, extremity, and lens of the eye doses are given. It is not in the scope of this document to consider exposure due to alpha radiation fields. NOTE 1 The requirements for the monitoring of the occupational exposure may be given in national regulations. NOTE 2 Dose to the lens of the eye due to intake of tritium is not in the scope of this document. Moreover, the situation of the workers that work in contaminated atmosphere and can have alpha and/or radon eye lens dose is also not in the scope.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 15382-2025 PDF

ISO 15382-2025 PDF

$113.50 $227.00