Washer-disinfectors — Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-critical thermolabile medical devices and health care equipment
Introduction: This document is the seventh part of the ISO 15883 series of standards specifying the performance of washer-disinfectors (WD) and the general requirements for performance applicable to instrument WD. The requirements given in this document apply to WD used for cleaning and chemical disinfection of non-critical thermolabile medical devices and health care equipment without further treatment in health care settings. Such reusable equipment is cleaned and disinfected, but processing in a WD for surgical instruments (see ISO 15883-2), for human waste containers (see ISO 15883-3), for endoscopes (see ISO 15883-4), or for thermal disinfection of non-critical medical devices and health care equipment (see ISO 15883-6), is inappropriate and/or impractical. Examples of the equipment to which this document applies are beds and bedside furniture, trolleys and transport carts, operating tables, footwear, wheelchairs, or aids for people with disabilities. Requirements for WD for other applications are specified in other parts of ISO 15883. Safety requirements for WD are given in IEC 61010-2-040. The quality of water to be used in a WD is covered in ISO/TS 5111. NOTE Local or national regulations can apply in respect of the potential adverse effects on the quality of water intended for human consumption or environmental impacts caused by the WD and its intended use. © ISO 2025 – All rights reserved
Scope: This document specifies the requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as: a) bed frames; b) bedside tables; c) transport carts; d) containers; e) surgical tables; f) sterilization containers; g) surgical clogs; h) wheelchairs; i) aids for persons with disabilities. This document also specifies the performance requirements for the cleaning and disinfection of the WD and its components and accessories. Devices identified within the scopes of ISO 15883-2, ISO 15883-3, ISO 15883-4, and ISO 15883-6 do not fall within the scope of this document. In addition, this document specifies the methods for type testing, works testing, validation (installation, operation, and performance qualification on first installation), routine control, and monitoring, as well as requalifications to be carried out periodically and after essential repairs. NOTE 1 WD covered by this document can also be used for cleaning and chemical disinfection of other thermolabile and reusable devices as recommended in the instructions for use (IFU) for those devices. NOTE 2 The performance requirements specified in this document cannot ensure the inactivation or removal of the causative agent(s) (prion proteins) of transmissible spongiform encephalopathies.