Methods for the calibration of vibration and shock transducers-Part 34: Testing of sensitivity at fixed temperatures

$71.50 $143.00 -50%
Product Code: ISO 16063-34
Stock In Stock
Edition: 1ST
Published: 12/2019
Number of Pages: 24
File Size: 1 file, 1 Byte

Available Options

Product Description

Methods for the calibration of vibration and shock transducers — Part 34: Testing of sensitivity at fixed temperatures

Introduction: The purpose of this document is to establish the procedures for testing the complex sensitivity of vibration transducers at fixed temperatures in the temperature range from –190 °C to 800 °C and frequency range from 10 Hz to 3 kHz. The three methods described in this document allow the determination of the complex sensitivity or temperature response of complex sensitivity of a transducer to sinusoidal vibration in the temperature chamber. Principles, procedures, and uncertainties of calibrations such as a comparison to a reference transducer or an absolute measurement by laser interferometer are given in this document. Calibrations are carried out using one of the three methods, depending on the different principles to be used and the temperature and frequency range limitations. © ISO 2019 – All rights reserved

Scope: This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers. The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer. This document is applicable for a frequency range from 10 Hz to 3 kHz (method-dependent), a dynamic range from 1 m/s2 to 100 m/s2 (frequency-dependent) and a temperature range from –190 °C to 800 °C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them. Method 1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 3 kHz at fixed temperatures (see Clause 7). Method 2 (using a reference transducer inside a chamber whose temperature limit is –70 °C to 500 °C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 1 kHz at fixed temperatures (see Clause 8). Method 3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause 9). NOTE Method 1 and Method 2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23 °C ± 5 °C). To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16063-34-2019 PDF

ISO 16063-34-2019 PDF

$71.50 $143.00