Evaluation of thickness, density and interface width of thin films by X-ray reflectometry — Instrumental requirements, alignment and positioning, data collection, data analysis and reporting
Introduction: X-Ray Reflectometry (XRR) is widely applicable to the measurement of thickness, density and interface width of single layer and multi-layered thin films which have thicknesses between approximately 1 nm and 1 μm, on flat substrates, provided that the layer, equipment and X-ray wavelength are appropriate. Interface width is a general term; it is typically composed of interface or surface roughness and/or density grading across an interface. The specimen needs to be laterally uniform under the footprint of the X-ray beam. In contrast with typical surface chemical analysis methods which provide information of the amount of substance and need conversion to estimate thicknesses, XRR provides thicknesses directly traceable to the unit of length. XRR is very powerful method to measure the thickness of thin film with SI traceability. The key requirements for equipment suitable for collecting specular X-ray reflectivity data of high quality, and the requirements for specimen alignment and positioning so that useful, accurate measurements may be obtained are described in Clause 4. The key issues for data collection to obtain specular X-ray reflectivity data of high quality, suitable for data treatment and modelling are described in Clause 5. The collection of the data is traditionally conducted by running single measurements under direct operator data input. However, recently data are often collected by instructing the instrument to operate in multiple runs. In addition to the operator
Scope: This document specifies a method for the evaluation of thickness, density and interface width of single layer and multi-layered thin films which have thicknesses between approximately 1 nm and 1 μm, on flat substrates, by means of X-Ray Reflectometry (XRR). This method uses a monochromatic, collimated beam, scanning either an angle or a scattering vector. Similar considerations apply to the case of a convergent beam with parallel data collection using a distributed detector or to scanning wavelength, but these methods are not described here. While mention is made of diffuse XRR, and the requirements for experiments are similar, this is not covered in the present document. Measurements may be made on equipment of various configurations, from laboratory instruments to reflectometers at synchrotron radiation beamlines or automated systems used in industry. Attention should be paid to an eventual instability of the layers over the duration of the data collection, which would cause a reduction in the accuracy of the measurement results. Since XRR, performed at a single wavelength, does not provide chemical information about the layers, attention should be paid to possible contamination or reactions at the specimen surface. The accuracy of results for the outmost layer is strongly influenced by any changes at the surface. NOTE 1 Proprietary techniques are not described in this document.