Surface chemical analysis — Depth profiling — Methods for ion beam alignment and the associated measurement of current or current density for depth profiling in AES and XPS

Introduction: In surface chemical analysis with Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS), ion sputtering has been extensively incorporated for surface cleaning and for the in-depth characterization of layered structures in many devices and materials. Currently, ultra- thin films of < 10 nm thickness are increasingly used in modern devices and so lower energy ions are becoming more important for depth profiling. For reproducible sputtering rates and for good depth resolution, it is important to align the ion beam at the optimal position. This optimization becomes increasingly critical as better and better depth resolutions are required. It is not necessary to conduct a beam alignment routinely but it is necessary to align the beam when instrument parameters change as a result of, for example, replacement of ion-gun filaments or an instrument bake-out. During the beam alignment, care must be taken not to sputter or otherwise affect samples for analysis on the sample holder. Instruments have different facilities to conduct alignment and six methods are described to ensure that most analysts can conduct at least one method. Two of these methods are also useful for measuring the ion beam current or the current density – important when measuring sputtering yields and for measuring sputtering rate consistency. With commercial instruments, the manufacturer may provide a method and equipment to conduct the beam alignment. If this is adequate, the methods describe

Scope: This document specifies methods for the alignment of the ion beam to ensure good depth resolution in sputter depth profiling and optimal cleaning of surfaces when using inert gas ions in Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS). These methods are of two types: one involves a Faraday cup to measure the ion current; the other involves imaging methods. The Faraday cup method also specifies the measurements of current density and current distributions in ion beams. The methods are applicable for ion guns with beams with a spot size less than or equal to 1 mm in diameter. The methods do not include depth resolution optimization.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16531-2020 PDF

ISO 16531-2020 PDF

$96.50 $193.00