ISO 16773-3-2016 PDF

ISO 16773-3-2016 PDF

Electrochemical impedance spectroscopy (EIS) on coated and uncoated metallic specimens - Part 3: Processing and analysis of data from dummy cells

$48.00 $96.00 -50%
Product Code: ISO 16773-3
Stock In Stock
Edition: 2ND
Published: 04/01/2016
Number of Pages: 16
File Size: 1 file, 420 Bytes

Available Options

Product Description

Electrochemical impedance spectroscopy (EIS) on coated and uncoated metallic specimens - Part 3: Processing and analysis of data from dummy cells

Scope: This part of ISO 16773 specifies a procedure for the evaluation of the experimental set-up used for carrying out EIS on high-impedance coated samples. For this purpose, dummy cells are used to simulate high-impedance coated samples. On the basis of the equivalent circuits described, this part of ISO 16773 gives guidelines for the use of dummy cells to increase confidence in the test protocol, including making measurements, curve fitting and data presentation. NOTE Due to the nature of the measurements, investigations of high-impedance coated samples are more susceptible to artefacts coming from electromagnetic interferences. Therefore, this part of ISO 16773 considers the aspects for measuring high-impedance samples by using appropriate dummy cells in a Faraday cage. However, most manufacturers offer complementary dummy cells in the low and medium impedance range. This allows checking the setup in the respective low impedance range. 2 Description of the dummy cells 2.1 General A set of four equivalent circuits (dummy cells) is used to check the overall experimental arrangement. The dummy cells are mounted separately. Two types of equivalent circuit, A and B, are used, as shown in Figure 1. The specific electrical components of these four cells are given in Table 1. Dummy cells with low impedance values (10 Ω to 1 000 Ω) are described in ISO/TR 16208. NOTE In Clause 8, the results of an interlaboratory test are used to evaluate the precision of this method. During the interlaboratory test, the participating laboratories also measured a fifth dummy cell consisting of an equivalent circuit of type B with unknown component values. 2.2 Components of the dummy cells Each dummy cell consists of a combination of resistors and capacitors which are soldered directly onto a printed-circuit board (see Figures 1 and 2). Such networks of resistors and capacitors (equivalent circuits) are often used in work on high-impedance coated specimens. NOTE Because of the very high overall resistance of circuits A and B, the resistor simulating the electrolyte can be neglected. Typically, the values of resistances R1 and R2 are above 100 MΩ whereas the electrolyte resistance is around 1

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16773-3-2016 PDF

ISO 16773-3-2016 PDF

$48.00 $96.00