ISO 17099-2024 PDF

ISO 17099-2024 PDF

Radiological protection-Performance criteria for laboratories using the cytokinesis-block micronucleus (CBMN) assay in peripheral blood lymphocytes for biological dosimetry

$60.00 $120.00 -50%
Product Code: ISO 17099
Stock In Stock
Edition: 2.
Published: 06/2024
Number of Pages: 44
File Size: 1 file, 2 Bytes

Available Options

Product Description

Radioprotection - Critères de performance pour les laboratoires pratiquant la dosimétrie biologique par le test des micronoyaux avec blocage de la cytodiérèse (CBMN) dans les lymphocytes du sang périphérique

Introduction: The purpose of this document is to define the use of the cytokinesis-block micronucleus (CBMN) assay with human peripheral blood lymphocytes for biological dosimetry of exposure to ionizing radiation. This assay is intended to be applied for accidental or malevolent exposures involving a) up to a few casualties to provide individual whole-body dose estimates, or b) in a triage mode to populations to provide rapid, lower accuracy dose estimates for individuals that can be improved with more accurate analysis at a later time. The CBMN assay is an alternative cytogenetic technique, which is possibly simpler and faster to perform than the dicentric assay[1][2]. It is also routinely used to demonstrate exposure to genotoxic agents, other than ionizing radiation, which is not covered in this document. Although culture of the blood samples is slightly longer than for dicentrics, the scoring of micronuclei (MN) in binucleated lymphocytes is easier. As was done with the dicentric assay, the CBMN assay has been adapted for the emergency triage of large- scale multi-casualty nuclear or radiological incident. The blood volume required for a sufficient number of scorable binucleated cells (BNCs) is similar to that required for the dicentric assay. Again, the faster counting speed for MN compensates for the extended culture time. However, it has to be considered that factors such as age, sex, diet and environmental mutagens can have an influence on the results particularly after low dose e

Scope: This document gives guidance on a) confidentiality of personal information for the customer and the laboratory, b) laboratory safety requirements, c) calibration sources and calibration dose ranges useful for establishing the reference dose-response curves that contribute to the dose estimation from CBMN assay yields and the detection limit, d) performance of blood collection, culturing, harvesting, and sample preparation for CBMN assay scoring, e) scoring criteria, f) conversion of micronucleus frequency in BNCs into an estimate of absorbed dose, g) reporting of results, h) quality assurance and quality control, and i) informative annexes containing sample instructions for customers, sample questionnaire, a microscope scoring data sheet, and a sample report. This document excludes methods for automated scoring of CBMN.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 17099-2024 PDF

ISO 17099-2024 PDF

$60.00 $120.00