ISO 17973-2024 PDF

ISO 17973-2024 PDF

Surface chemical analysis-Medium-resolution Auger electron spectrometers-Calibration of energy scales for elemental analysis

$48.00 $96.00 -50%
Product Code: ISO 17973
Stock In Stock
Edition: 3.
Published: 07/2024
Number of Pages: 18
File Size: 1 file, 1 Byte

Available Options

Product Description

Surface chemical analysis — Medium-resolution Auger electron spectrometers — Calibration of energy scales for elemental analysis

Introduction: Auger electron spectroscopy (AES) is used extensively for the surface analysis of materials. Elements in the sample (with the exception of hydrogen and helium) are identified from comparisons of the peak energies and peak shapes, with tabulations of peak energies and data in handbooks of spectra for the different elements. To identify the peaks, calibration of the energy scale with an uncertainty of 3 eV is generally adequate, and this document is only intended for work at that level of accuracy (for greater accuracy, see ISO 17974). The method for calibrating kinetic energy scales specified in this document uses metallic samples of pure copper (Cu) and either aluminium (Al) or gold (Au). It does not include tests for defects in the instrument, since few defects are significant at the level of accuracy concerned. Traditionally, kinetic energies of Auger electrons have been referenced to the vacuum level, and this reference is still used by many analysts. However, the vacuum level is ill-defined and can vary from instrument to instrument over a range of 0,5 eV. Although use of the vacuum level reference procedure will generally not cause ambiguity in elemental identification, it can cause uncertainty in measurements at high resolution relating to chemical states. Because of this, instruments designed for both Auger electron spectroscopy and X-ray photoelectron spectroscopy reference the kinetic energies to the Fermi level, giving values typically 4,5 eV higher than those refer

Scope: This document specifies a method for calibrating the kinetic energy scales of Auger electron spectrometers with an uncertainty of 3 eV, for general analytical use in identifying elements at surfaces. This document also specifies a method for establishing a calibration schedule. It is applicable to instruments used in either direct or differential mode, where the resolution is less than or equal to 0,5 % and the modulation amplitude for the differential mode, if used, is 2 eV peak-to-peak. It is applicable to those spectrometers equipped with an inert gas ion gun or other method for sample cleaning and with an electron gun capable of operating at 4 keV or higher beam energy.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 17973-2024 PDF

ISO 17973-2024 PDF

$48.00 $96.00