Condition monitoring and diagnostics of power transformers

Introduction: This document provides guidance for condition monitoring and diagnostics of power transformers using parameters (such as oil condition, oil contamination, dielectric condition, temperature, power, voltage and current) typically associated with performance, condition and quality criteria. The evaluation of the power transformer function and condition may be based on performance, condition or output quality. This document is aimed at asset managers, equipment specifiers, owners, operators and reliability and maintenance engineers. It provides a selection process “road map”. The parameters and techniques are directed towards best-practice condition-based maintenance, detecting fault conditions, directing maintenance decisions and estimating asset health. It is principally aimed at people who are not transformer experts, but who have a small number of transformers; for example, supplying power into a manufacturing site where many other items of equipment depend on the power continuing to be supplied by the transformers. The upper limit for the size of such transformers is probably around 50 MVA. While the same principles will also apply to owners and operators of large numbers of transformers such as utilities, which can exceed 50 MVA, it is expected that they will already have their own internal company guidelines and procedures for monitoring their transformers and so are not the primary target of this document. This document follows on from ISO 17359, which outlines the genera

Scope: This document gives guidelines for the monitoring techniques to be considered when setting up a condition monitoring programme for power transformers and includes references to associated standards required in this process. It is intended to help in the implementation of a coherent condition monitoring and condition-based maintenance programme, such as described following ISO 17359. This document is applicable to single-phase alternating current power transformers of ≥ 1 kVA and three phase alternating current power transformers of ≥ 5 kVA.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18095-2018 PDF

ISO 18095-2018 PDF

$129.00 $258.00