ISO 18127-2026 PDF

ISO 18127-2026 PDF

Water quality-Determination of adsorbable organically bound fluorine, chlorine, bromine and iodine (AOF, AOCl, AOBr, AOI)-Method using combustion and subsequent ion chromatographic measurement

$129.00 $258.00 -50%
Product Code: ISO 18127
Stock In Stock
Edition: 1.
Published: 02/2026
Number of Pages: 52
File Size: 1 file, 1.8 MB

Available Options

Product Description

Water quality — Determination of adsorbable organically bound fluorine, chlorine, bromine and iodine (AOF, AOCl, AOBr, AOI) — Method using combustion and subsequent ion chromatographic measurement

Introduction: Adsorbable organically bound fluorine, chlorine, bromine and iodine are analytical convention parameters used to monitor water quality. They represent the sum of organically bound fluorine, chlorine, bromine and iodine that can be adsorbed on activated carbon under specified conditions and, if the sample has not been filtered, can also be attached to or contained in suspended substances. In contrast to the adsorbable organically bound halogen (AOX) method according to ISO 9562, this method can be applied to determine the sum of organofluorine compounds in addition to the determination of the organically bound chlorine, bromine and iodine and detected halogen-specific separately. The method is carried out by combustion ion chromatography (CIC). Procedures for each separate parameter are described in Annex A, Annex B, Annex C and Annex D. Alternatively, the adsorption of the organic substances contained in the water sample on activated carbon can also be carried out by the shaking method (see Annex E). Samples with a high content of suspended solids can be analysed using the shaking method (see Annex E). Samples with a high content of inorganic halides can be analysed using the solid phase extraction (SPE) method (see Annex F). Results for samples analysed according to Annex E (shaking procedure) or Annex F (SPE procedure) can differ significantly from those of the method specified in the main part. With some waters, interference can occur that cannot be eliminated. These water

Scope: This document specifies a method for the determination of organically bound halogens fluorine, chlorine, bromine and iodine which are adsorbable on activated carbon. Adsorption takes place on activated carbon packed in columns. The method is applicable for the determination of: — ≥ 2 µg/l AOF, expressed as F; — ≥ 10 µg/l AOCl, expressed as Cl; — ≥ 1 µg/l AOBr, expressed as Br; — ≥ 1 µg/l AOI, expressed as I. The method is applicable for the determination of adsorbable organically bound fluorine, chlorine, bromine and iodine in water, e.g. in groundwater, surface water, bank filtrate, drinking water, aqueous eluates, cooling water and wastewater. The working range is limited by the capacity of the activated carbon, the process blank and the capacity of the chromatographic separation column. Sample dilution into the working range can be required. The range of application can be extended to lower concentrations with lower process blanks e.g. using low blank activated carbons. The method can also be applied for samples containing suspended solids. Halogens adsorbed on the suspended solids (e.g. undissolved halides) are also determined. Filtration of the sample prior to analysis using a membrane filter (0,45 µm) allows the separate determination of dissolved adsorbable and particulate bound fractions of organically bound fluorine, chlorine, bromine or iodine. Results from an international interlaboratory trial are presented in Annex K.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18127-2026 PDF

ISO 18127-2026 PDF

$129.00 $258.00