Cardiovascular implants and extracorporeal systems - Centrifugal blood pumps

$13.00 $26.00 -50%
Product Code: ISO 18242
Stock In Stock
Edition: 1.
Published: 09/01/2016
Number of Pages: 18
File Size: 1 file, 408 Bytes

Available Options

Product Description

Cardiovascular implants and extracorporeal systems - Centrifugal blood pumps

Introduction: This document is intended to ensure that devices designed to provide continuous flow of blood in support of, or as a substitution for, the normal pumping function of the heart have been adequately tested for both their safety and function, and that extracorporeal device characteristics are appropriately disclosed when labelling the device. This document therefore contains procedures to be used for evaluation of extracorporeal centrifugal blood pumps. Test procedures for determination of the hydraulic performance, blood cell damage and other performance characteristics are described, although limits for these characteristics are not specified. Ready identification of the performance characteristics should, however, assist the user in the selection of a centrifugal blood pump that will suit the needs of the patient. This document also includes minimum reporting requirements, which will allow the user to compare performance characteristics of centrifugal blood pumps of different designs in a standard way. This document makes reference to other International Standards in which methods for determination of characteristics common to medical devices can be found. Requirements for animal and clinical studies have not been included in this document. Such studies may be part of a manufacturer’s quality system. This document contains only those requirements that are specific to centrifugal blood pumps. Non- specific requirements are covered by references to other International Standards

Scope: This document specifies requirements for sterile, single-use, extracorporeal centrifugal blood pumps, whether coated, non-surface modified, or surface-modified, intended for producing blood flow during extracorporeal circulation. Such blood flow is most commonly used to provide systemic perfusion during cardiopulmonary bypass, but also has applications for veno-venous bypass, kinetic-assisted venous drainage, or extracorporeal membrane oxygenation. This document does not apply to — centrifugal pumps used as ventricular assist devices, and — other components of extracorporeal circuits (e.g. blood tubing, pump console/driver).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18242-2016 PDF

ISO 18242-2016 PDF

$13.00 $26.00