ISO 18566-2-2017 PDF

ISO 18566-2-2017 PDF

Building environment design - Design, test methods and control of hydronic radiant heating and cooling panel systems - Part 2: Determination of heating and cooling capacity of ceiling mounted radiant panels

$71.50 $143.00 -50%
Product Code: ISO 18566-2
Stock In Stock
Edition: 1ST
Published: 06/2017
Number of Pages: 24
File Size: 1 file, 684 Bytes

Available Options

Product Description

Building environment design - Design, test methods and control of hydronic radiant heating and cooling panel systems - Part 2: Determination of heating and cooling capacity of ceiling mounted radiant panels

Introduction: The radiant heating and cooling system consists of heat emitting/absorbing, heat supply, distribution, and control systems. Typical applications are low temperature radiant heating and high temperature radiant cooling. They are classified as embedded radiant heating and cooling systems and prefabricated radiant heating and cooling panel systems. While ISO 11855 is for embedded radiant heating and cooling systems without an open air gap, ISO 18566 is for radiant heating and cooling panel systems with an open air gap. Because the system specifications for ISO 18566 are different from those of ISO 11855, it was necessary to develop separate ISO standards regarding the design and test methods of the cooling and heating capacity and control. ISO 18566-1 specifies the comfort criteria, technical specifications and requirements which should be considered in the manufacturing and installation of radiant heating and cooling systems. ISO 18566-2 provides the test facility and test method for heating and cooling capacity of ceiling mounted radiant panels. ISO 18566-3 specifies the design considerations and design processes of ceiling mounted radiant panels. ISO 18566-4 addresses the control of ceiling mounted radiant heating and cooling panels to ensure the maximum performance which was intended in the design stage when the system is actually being operated in a building. ISO 18566 does not cover the panels that are embedded into the ceiling, wall or floor structure. This document deals

Scope: This document defines technical specifications and requirements of free hanging (suspended) heating and dry cooling only surfaces with an air gap between construction and the emitter (not embedded) with or without an insulation fed with water at temperatures below 120 °C connected with a centralized heating and/or cooling supply source intended to be installed in buildings. Ceiling mounted radiant panels covered by this document are limited to a width from 0,3 m up to 1,5 m. This document also defines the additional common data that the manufacturer provides to the trade, in order to ensure the correct application of the products.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18566-2-2017 PDF

ISO 18566-2-2017 PDF

$71.50 $143.00