Imaging materials — Methods for measuring indoor light stability of photographic prints — Part 1: General guidance and requirements
Introduction: This document addresses the methods for measuring the indoor light stability of reflection prints, and transparent or translucent films, both colour and monochrome[10][18] to [23][24] to [30].Outdoor light stability is addressed in ISO 18930, with additional background referenced in ISO TR 18945. This document focuses on general guidance, which includes aspects of the testing that applies to all of the other specific parts, including minimum performance requirements of the instruments used, details of control systems, calibration requirements, test specimen development, and reporting requirements. ISO 18937-2 focuses on exposures using xenon-arc lamps. ISO 18937-3 focuses on exposures using LED lamps. Specific testing requirements based on simulation to the defined use cases and capabilities of the instruments are included in ISO 18937-2 and ISO 18937-3 documents. The length of time that such photographs are to be kept can vary from a few days to many hundreds of years and the importance of image stability can be correspondingly small or great. Often the ultimate use of a particular photograph may not be known at the outset. If display is part of the intended use, knowledge of the lightfastness level of colour photographs is important to manufacturers to improve print materials and to many users to match their display longevity expectations for any given use profile, especially since stability requirements may vary depending upon the application. The images of most modern ana
Scope: This document provides information and general guidance about the methods for measuring the indoor light stability of reflection prints, both colour and monochrome, transparent or translucent films, and photographic prints for backlit displays. This document is relevant to the selection and operation of the methods of exposure to radiation and environmental stress factors described in detail in subsequent parts. It also describes general performance requirements for devices used for exposing printed material to laboratory light sources. Information regarding performance requirements is for producers of artificial accelerated lightfastness devices. NOTE In this document, the term “light source” refers to radiation sources that emit UV radiation, visible radiation, infrared radiation, or any combination of these types of radiation. This document does not include test procedures for determining the effects of light exposure on the physical stability of images, supports, or binder materials. However, it is recognized that in some instances, physical degradation such as support embrittlement, image layer cracking, or delamination of an image layer from its support, rather than the stability of the image itself, determines the useful life of a print material. Print image stability results determined for one printer model, software settings, colorant, and media combination may not be applicable to another combination.