Radioprotection - Critères de performance pour les laboratoires de service pratiquant la dosimétrie biologique par cytogénétique

Introduction: The widening use of ionising radiations for medical, industrial, agricultural, research, and military purposes increases the risk of overexposure of radiation workers and individuals of the general population. Biological dosimetry, based on the study of chromosomal aberrations, mainly through the dicentric assay, has become a routine component of accidental dose assessment. Experience with its application in hundreds of cases of suspected or verified overexposures has proven the value of this method and also defined its limitations. It should be emphasized that dicentric chromosome analysis is used as a dosimeter and provides one input into the compendium of information needed for assessment of a radiological incident. Many studies on animals and humans have shown that one can establish a good correlation between the results obtained in vivo and in vitro, so that in vitro established dose-effect relationships from irradiated blood samples can be used to form calibration curves. The dicentric yield is dependent on radiation quality and dose rate, as well as the circumstances of exposure, for example time since exposure, homogeneity, so information about these variables is important for each investigation. If known, these exposure characteristics are important for refining the aberration dose estimates. The specificity of this technique is enhanced by the fact that generally 1 dicentric is observed per 1 000 metaphase spreads in the normal population, and that this frequency is

Scope: This document provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories using the dicentric assay performed with manual scoring. This document is applicable to a) the confidentiality of personal information, for the requestor and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose- response curves that contribute to the dose estimation from unstable chromosome aberration frequency and the detection limit, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, and h) informative annexes containing sample instructions for requestor (see Annex A), sample questionnaire (see Annex B), sample report (see Annex C), fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of the dose estimate (see Annex D), odds ratio method for cases of suspected exposure to a low dose (see Annex E), a method for determining the decision threshold and detection limit (see Annex F) and sample data sheet for recording aberrations (see Annex G).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 19238-2023 PDF

ISO 19238-2023 PDF

$60.00 $120.00