Determination of the resistance to cryogenic spill of insulation materials-Part 2: Vapour exposure

$71.50 $143.00 -50%
Product Code: ISO 20088-2
Stock In Stock
Edition: 1ST
Published: 01/2020
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Determination of the resistance to cryogenic spill of insulation materials — Part 2: Vapour exposure

Introduction: The test is intended to be, as far as practicable, representative of a potential accidental pressurised release of cryogenic LNG material manufactured in industrial plants. The test includes a) release from of cryogenic liquid under pressure, and b) scenarios where the conditions in the jet characterized predominantly by gaseous exposure. Liquid jet release may be formed upon release of Liquified Natural Gas (LNG) from process equipment operating at pressure, e.g., some liquefaction processes utilise 40 - 60 bar operating pressure. However, at specific distances from the release point, it is expected that the liquid fraction will diminish such that there is practically no effect from liquid cooling in the stream. This test is designed to give an indication of how cryogenic spill protection materials will perform in a sudden exposure to cryogenic jet where it is expected that little or no liquid fraction is present. The dimensions of the test specimen might be smaller than typical items of structure and plant. The liquid cryogenic jet mass flow rates can be substantially less than that which might occur in a credible event. However, individual thermal loads imparted to the cryogenic spill protection materials, from the cryogenic release defined in the procedure described in this document, have been shown to be representative of areas exposed to a cryogenic LNG accidental release where little or no liquid is present. © ISO 2020 – All rights reserved

Scope: This document describes a method for determining the resistance of Cryogenic Spill Protection (CSP) systems to vapour generated from a cryogenic liquid release where the liquid content is practically zero. It is applicable where CSP systems are installed on carbon steel. The test provided in this document is not applicable to high pressure cryogenic liquid releases that can be found in refrigeration circuits and in LNG streams immediately post-liquefaction.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 20088-2-2020 PDF

ISO 20088-2-2020 PDF

$71.50 $143.00